ArticleSensors (Basel, Switzerland)2026
A Sustainable Natural-Rubber IoT Smart Insole for Remote Body-Load Monitoring: An Observational Gait Comparison in Flexible Flatfoot.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Flexible flatfoot (pes planus) alters lower-limb biomechanics and plantar-pressure distribution, raising the risk of pain and injury. Laboratory gait analysis with optical motion capture and force plates is the reference standard but is costly, space-constrained, and ecologically limited. We present the design, fabrication, and validation of a low-cost, sustainable smart insole for Internet-of-Things (IoT) remote body-load monitoring. The device pairs a dual-layer natural-rubber body-a silica-filled sponge-rubber upper for comfort and a carbon-black-reinforced solid outsole for durability-with four load cells per insole at high-pressure plantar landmarks, read through a 24-bit amplifier by an ESP32 that calibrates and streams left/right load over Wi-Fi to the ThingSpeak cloud, with a wrist-worn OLED for real-time feedback. Against reference weights in 25 participants, the system measured total body weight with a mean absolute error of 2.94%, a maximum error of 4.18%, and an RMSE of 1.94 kg (Pearson r = 0.99); the residual was an almost purely systematic proportional bias (slope 0.966, R
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.