Evidence map›Paper›PMID 42811247›Full record

ArticleAnnals of biomedical engineering2026

A Preclinical Approach to 3D-Printed Osseointegration Prosthesis: Improving Functional Outcomes and Reducing Complications in Residual Limb Reconstruction.

Shuaihe Gong, Yifan Wang, Chang Zhou, Jiale Li, Kexin Xie, Wei Guo, Yi Yang, Jun Wang

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shuaihe Gong *Department of Musculoskeletal Tumor, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China.
Yifan Wang *Department of Musculoskeletal Tumor, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China.
Chang ZhouDepartment of Musculoskeletal Tumor, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China.
Jiale LiDepartment of Musculoskeletal Tumor, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China.
Kexin XieDepartment of Musculoskeletal Tumor, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China.
Wei GuoDepartment of Musculoskeletal Tumor, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China.
Yi YangDepartment of Musculoskeletal Tumor, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China.
Jun WangDepartment of Musculoskeletal Tumor, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China. pkuwangjun@bjmu.edu.cn.

Funding

Beijing Natural Science Foundation Innovation Joint Fund L248060National Natural Science Foundation of China 82272947The Research and Development Fund of Peking University People's Hospital RDL2022⁃14The Research and Development Fund of Peking University People's Hospital RZ2023-02
6 · The paper itself

Abstract

This study presented a novel additively manufactured osseointegration prosthesis (OIP) for patients with amputation residual limb functional reconstruction, elaborating its design concept, conducting finite element mechanical analysis, and evaluating efficacy via animal models to provide a clinical theoretical basis. Our designed OIP system were categorized into four types: Type I (solely intramedullary press-fit fixation) and Type II (combined intramedullary press-fit-extramedullary sleeve fixation); Type a (no auxiliary anti-rotation screws) and Type b (with such screws). The cloverleaf sleeve's inner wall and intramedullary stem surface featured 3D-printed metal porous structures. Finite element models were established using adult femoral CT data to simulate stress/displacement under 15,000/20,000 N*mm torque and 600/900 N vertical stress. A mid-femoral amputation model was constructed in Small-tailed Han sheep (n = 3), with Type IIa OIP press fitted after intramedullary cavity reaming and cortical decortication, evaluating functional reconstruction, biocompatibility, and osseointegration. Finite element analysis yielded stress peaks, maximum displacement, and distribution contour plots. Results showed cloverleaf sleeve-equipped prostheses had lower stress peaks under high vertical stress, more dispersed stress distribution, and superior displacement resistance. Animal model data demonstrated stable fixation, no obvious infection, and favorable prosthesis-femur osseointegration. This newly designed OIP possesses good biocompatibility and osseointegration capacity and the extramedullary cloverleaf sleeve enhances mechanical properties, laying a theoretical foundation for future clinical application.

Indexed as

3D printingFinite element analysisFunctional reconstructionOsseointegration prosthesis

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.