Evidence map›Paper›PMID 42811225›Full record

ArticleJournal of imaging informatics in medicine2026

Tomosynthesis and Synthesized-2D Breast AI Outputs in a Biopsy-Referred Cohort: A Diagnostic Study of Agreement and Incremental Decision-Support Value.

Erkan Şahin, Şimal Arslan, Kamil Doğan, Gülden Ballı, Avni Can Karaca, Isabel Raika Durusoy Onmuş, Baha Zengel

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of imaging informatics in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Erkan ŞahinDepartment of Radiology, İzmir University of Economics Medical Point Hospital, İzmir, Türkiye. erkan.sahin@medicalpoint.com.tr.ORCID http://orcid.org/0000-0002-1922-5280
Şimal ArslanDepartment of Radiology, İzmir University of Economics Medical Point Hospital, İzmir, Türkiye.ORCID http://orcid.org/0000-0002-1693-1227
Kamil DoğanDepartment of Radiology, İzmir University of Economics Medical Point Hospital, İzmir, Türkiye.
Gülden BallıDepartment of Radiology, İzmir University of Economics Medical Point Hospital, İzmir, Türkiye.
Avni Can KaracaDepartment of General Surgery, Izmir University of Economics Medical Point Hospital, İzmir, Türkiye.
Isabel Raika Durusoy OnmuşDepartment of Public Health, Faculty of Medicine, Ege University, İzmir, Türkiye.
Baha ZengelDepartment of General Surgery, Izmir University of Economics Medical Point Hospital, İzmir, Türkiye.ORCID http://orcid.org/0000-0002-1812-6846

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To determine whether two malignancy scores co-reported by a deployed breast artificial intelligence (AI) platform, one tomosynthesis-based and one synthesized-image-based, are interchangeable, and whether either adds information beyond clinical-radiological assessment. This single-center retrospective study analyzed 139 breast-level observations (84 malignant, 55 benign) from 134 biopsy-referred women, with histopathology as reference. Agreement between the two scores was assessed by paired comparison, by whether each output marked a lesion, and by threshold classification. A baseline logistic model (age, radiological suspicion, lesion size) was compared with models adding each score. Cancers negative by the tomosynthesis output at the cohort-derived threshold underwent targeted, AI-masked re-review. The outputs differed within individual breasts despite similar overall discrimination (area under the receiver operating characteristic curve [AUC] 0.728 versus 0.717; p = 0.786). Agreement was moderate (kappa = 0.53); among malignant breasts, 21 were flagged by the tomosynthesis output alone versus 6 by the synthesized output (p = 0.006). Adding either score improved model fit (p < 0.001), but discrimination gains were small (AUC 0.809 to 0.841-0.848) and decision-curve improvements uncertain. Of 30 cancers negative by the tomosynthesis output, 25 had no mammographic correlate on re-review, and breast density did not fully explain this pattern. Within this biopsy-referred cohort, the two AI outputs were not interchangeable. This supports treating co-reported outputs as distinct, context-dependent signals and not using a low AI score by itself to downgrade a suspicious finding. The reporting and governance implications require prospective multireader, multicenter validation.

Indexed as

Artificial intelligenceBreast cancerClinical decision supportDigital breast tomosynthesisImaging informaticsSynthesized mammography

Identifiers

PMID42811225

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.