Evidence map›Paper›PMID 42809061›Full record

ArticleLasers in medical science2026

Diffractive intraocular lenses reshape 577-nm retinal laser photocoagulation spots in a model eye.

Ke Wei, Fengtao Ji, Yongrong Li, Wei Dai, Rongfeng Liao

Abstract read
In one paragraph

Article in Lasers in medical science, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ke WeiDepartment of Ophthalmology, The First Affiliated Hospital of Anhui Medical University, Hefei, China.
Fengtao JiDepartment of Ophthalmology, Hefei Hospital Affiliated to Anhui Medical University (The Second People's Hospital of Hefei), Hefei, China.
Yongrong LiDepartment of Ophthalmology, Hefei Hospital Affiliated to Anhui Medical University (The Second People's Hospital of Hefei), Hefei, China.
Wei DaiDepartment of Ophthalmology, Hefei Hospital Affiliated to Anhui Medical University (The Second People's Hospital of Hefei), Hefei, China.
Rongfeng LiaoDepartment of Ophthalmology, The First Affiliated Hospital of Anhui Medical University, Hefei, China. liaorfayfy@126.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To evaluate whether diffractive intraocular lenses (IOLs) reshape 577-nm retinal laser photocoagulation spots in a model eye. A standardized model eye received 577-nm continuous-wave laser photocoagulation through a retinal contact lens at fixed settings: 200-µm spot, 100 mW, and 0.2 s. One monofocal IOL (ZCB00) and two diffractive IOLs (ZMB00, ZXR00) were tested in 15 sessions; a no-IOL condition provided power normalization and quality control. Delivered power was measured calorimetrically and normalized to no-IOL controls. Thermal-paper responses were threshold-segmented to quantify core fraction and disk area. Session-blocked models compared pooled r = 3 mm values; C-to-r = 3 mm changes were used to assess field-dependent effects. At pooled r = 3 mm, core fraction was 0.406 (95% CI, 0.382-0.430) for ZCB00, 0.179 (0.155-0.203) for ZMB00, and 0.201 (0.177-0.225) for ZXR00. Mean differences versus ZCB00 were - 0.227 (95% CI, - 0.261 to - 0.193) for ZMB00 and - 0.205 (- 0.239 to - 0.171) for ZXR00 (both Holm-adjusted P < 0.001). Disk area ratios versus ZCB00 were 0.754 (95% CI, 0.704 to 0.808) for ZMB00 and 0.682 (0.637 to 0.731) for ZXR00 (both Holm-adjusted P < 0.001). Normalized delivered power remained close to unity (0.993-0.997). C-to-r = 3 mm comparisons showed larger morphology changes for diffractive IOLs, whereas normalized delivered power changed little with radius. Under the specified 577-nm model-eye conditions, the tested diffractive bifocal and EDOF IOLs altered threshold-defined photothermal spot morphology relative to the monofocal control, while normalized aperture-integrated power remained near unity, suggesting field-dependent redistribution of target-plane irradiance.

Indexed as

Laser CoagulationLenses, IntraocularRetinaHumansDiffractive intraocular lensIntraocular lens opticsLaser deliveryModel eyePhotothermal responseRetinal laser photocoagulation

Identifiers

PMID42809061
PMCPMC13623784

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.