Evidence map›Paper›PMID 42807564›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2026

Squint ASSIST: A Novel Application Program for Detecting Strabismus and Measuring Angle of Deviation.

Nichakant Srisaenpang, Nutta Homdee, Yosanan Yospaiboon, Sirinya Suwannaraj

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Nichakant SrisaenpangDepartment of Ophthalmology, KKU Eye Center, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.
Nutta HomdeeCenter for Research Innovation and Biomedical Informatics, Faculty of Medical Technology, Mahidol University, Bangkok, Thailand.
Yosanan YospaiboonDepartment of Ophthalmology, KKU Eye Center, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.ORCID 0000-0003-0081-0102
Sirinya SuwannarajDepartment of Ophthalmology, KKU Eye Center, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To develop and validate Squint ASSIST (Squint Automatic Strabismus Sizing using Image Sensing Technology), an application program for strabismus detection and angle measurement, using corneal light reflex deviation in eye photographs. Methods: This prospective cross‑sectional clinic‑based study enrolled 136 patients and 1384 photographs. Two analytic methods were evaluated: Method 1 (inter-ocular comparison; comparing corneal light reflex positions between both eyes in one image) and Method 2 (intra‑ocular comparison; comparing the same eye in a straight vs deviated image). Photographs were processed with standardized processing images. The participants' angles of deviation were measured using this program, which converts the light reflex deviation to misaligned angles in prism diopters. The main outcome was the sensitivity, specificity, and accuracy of the program for detecting strabismus. The agreement between the angles measured by the program and those measured by pediatric ophthalmologists using the Krimsky test and the Alternate Prism Cover Test (APCT) was analyzed using the Bland-Altman plot. Intra-observer and inter-observer reproducibility were also evaluated. Results: Of those 136 patients with strabismus, eighty‑seven patients had esotropia, 43 had exotropia, and six had orthophoria after strabismic surgery. The mean age was 12.8 (1-69) years. Squint ASSIST detected strabismus with high performance. Method 1: sensitivity 96.39%, specificity 94.34%, accuracy 95.59%; Method 2: sensitivity 96.83%, specificity 90.48%, accuracy 94.29%. Pearson Conclusions: The Squint ASSIST offers a reliable method for detecting and measuring strabismic angles in clinical settings. The small mean bias and strong intra-observer and inter-observer consistency support substantial clinical utility for screening, standardized photographic documentation, and telemedicine follow‑up. However, due to its wide limits of agreement for absolute angle estimates, pediatric ophthalmologists remain the reference for situations that demand maximal precision such as pre‑surgical planning.