Evidence map›Paper›PMID 42807359›Full record

ArticleJournal of dental research, dental clinics, dental prospects2026

Accuracy of Guided Implant Surgery Using Tomographic Guides Combined with Functional Impression: An In Vitro Study.

Renata Bommarito, Yolanda de Toledo Salvado da Ressurreição, Luciana Akemi Yamaguchi, Flavia Iotti Fernandes, Eduardo Perissinotto, Marcos Venturini Ferreira, Marcio Katsuyoshi Mukai, Roger Nishyama, Marcelo Munhóes Romano

Abstract read
In one paragraph

Article in Journal of dental research, dental clinics, dental prospects, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Renata BommaritoStomatology Department, University of São Paulo (USP), São Paulo, Brazil.ORCID https://orcid.org/0000-0001-9792-8144
Yolanda de Toledo Salvado da RessurreiçãoProsthodontic Department, University of São Paulo (USP), São Paulo, Brazil.ORCID https://orcid.org/0000-0002-2992-8633
Luciana Akemi YamaguchiStomatology Department, University of São Paulo (USP), São Paulo, Brazil.
Flavia Iotti FernandesStomatology Department, University of São Paulo (USP), São Paulo, Brazil.
Eduardo PerissinottoStomatology Department, University of São Paulo (USP), São Paulo, Brazil.
Marcos Venturini FerreiraStomatology Department, University of São Paulo (USP), São Paulo, Brazil.
Marcio Katsuyoshi MukaiProsthodontic Department, University of São Paulo (USP), São Paulo, Brazil.ORCID https://orcid.org/0000-0003-1608-7051
Roger NishyamaProsthodontic Department, University of São Paulo (USP), São Paulo, Brazil.ORCID https://orcid.org/0000-0003-0526-0381
Marcelo Munhóes RomanoStomatology Department, University of São Paulo (USP), São Paulo, Brazil.ORCID https://orcid.org/0000-0002-2672-2066

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Deviations between virtually planned and placed implants are still reported in guided implant surgery in completely edentulous arches. Associating a functional impression with the tomographic guide may enhance guide retention and reduce deviations. This study evaluated the effect of using a functional impression during tomographic image acquisition on the accuracy of implant placement in the edentulous maxilla. Methods: Fourteen 3D-printed edentulous maxillary models were fabricated. A complete denture was designed and printed for use as a tomographic guide for each model. During dual-scan image acquisition, the experimental group's tomographic guides were seated with a light-body silicone functional impression, whereas the control group was scanned without impression material (n=7). After image registration in Blue Sky Plan software, implants were virtually planned, and surgical guides were printed for the placement of six implants per model. Postoperative scans were obtained, and STL files of planned and placed implants were superimposed to measure linear and angular deviations. Statistical analysis was performed using two-way ANOVA for functional impression and implant region (α=0.05). Results: No statistically significant differences were found regarding the effects of functional impression or implant position ( Conclusion: The accuracy of implant positioning in edentulous maxillae was not significantly affected by the incorporation of a functional impression during tomographic scanning or by the implant region, although deviations were still observed. Further studies are necessary to evaluate the potential benefits of this approach in specific clinical scenarios.

Indexed as

Dental implantDimensional measurement accuracyEdentulous jawFunctional impressionGuided implant surgery

Identifiers

PMID42807359
PMCPMC13616825

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials