ArticleFrontiers in oncology2026
Modelling image quality over extended [
Article in Frontiers in oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03520218 (A Pilot Study to Evaluate Low-Dose Positron Emission Mammography Imaging in Visualization and Characterization of Suspicious Breast Abnormalities), which is not on this map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Pilot Study to Evaluate Low-Dose Positron Emission Mammography Imaging in Visualization and Characterization of Suspicious Breast Abnormalities
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: This study investigated the effect of [ Methods: Fifteen malignant lesions from thirteen women newly diagnosed with breast cancer were imaged using low-dose [ Results: Extending uptake times beyond the 1-hour clinical standard significantly improved CNR across all doses, with comparable proportional gains. Relative to 1 hour post-injection, CNR increased by approximately 30% at 1.5 hours, 53% at 2 hours, and 77% at 3 hours, although uncertainty widened at 3 hours and beyond, particularly at the lowest dose (1 mCi). Relatively small variations in uptake time were also found to produce substantial changes in the standardized uptake value (SUV). Discussion: These findings demonstrate that extending uptake times by even 30 minutes beyond the 1-hour clinical standard may significantly enhance image CNR for low-dose [ Clinical Trials Registration: https://clinicaltrials.gov/study/NCT03520218, identifier NCT03520218.