ArticleBMC oral health2026
Effect of power arm length and attachment configuration on maxillary molar mesialization with clear aligners: a finite element analysis.
Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMaxillary molar mesialization with clear aligners is challenging because achieving controlled root movement without excessive mesial tipping remains difficult. Although power arms can modify the force system, the combined effects of power-arm length and attachment configuration on molar displacement and tipping remain insufficiently characterized. This study evaluated the effects of 6-, 8-, and 10-mm power arms combined with two attachment configurations during maxillary first molar mesialization using three-dimensional finite element analysis.
methodsThe attachment configurations were selected to represent two clinically distinct approaches to integrating a vertical attachment with a power arm: a palatal vertical attachment combined with a buccal cut-out and a buccal vertical attachment with direct power-arm integration. Six three-dimensional finite element models were constructed by combining three power arm lengths (6, 8, and 10 mm) with two attachment configurations: a palatal vertical attachment with a buccal cut-out, and a buccal vertical attachment without a cut-out. A mesial force of 200 g was applied from a temporary anchorage device (TAD) to the power arm. Displacements were measured along the X (bucco-palatal), Y (mesio-distal), and Z (occluso-gingival) axes. Peak von Mises stress values in the periodontal ligament and aligner deformation were evaluated.
resultsIn all models, maxillary first molar displacement occurred predominantly in the mesial and gingival directions. Mesial crown displacement ranged from 0.068 to 0.074 mm, while distal displacement at the root apex ranged from 0.011 to 0.012 mm. Mesial tipping angles ranged from 0.155° to 0.170°, with higher tipping observed in models with shorter power arms. Increasing power arm length was consistently associated with reduced mesial tipping and lower periodontal ligament stress, but with reduced mesial crown displacement. Shorter power arms generated higher periodontal ligament stress, whereas longer power arms were associated with greater aligner deformation.
conclusionsPower arm length and attachment configuration were associated with differences in initial tooth displacement patterns, periodontal ligament stress distribution, and aligner deformation during maxillary first molar mesialization with clear aligners. Longer power arms were associated with reduced mesial tipping and lower periodontal ligament stress, but also with reduced mesial crown displacement. The buccal vertical attachment configuration consistently produced lower mesial rotation than the palatal vertical attachment with buccal cut-out configuration at each corresponding power-arm length; this difference should be interpreted as a configuration-dependent finding within the initial biomechanical response.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.