Evidence map›Paper›PMID 42802743›Full record

Trial reportDrug design, development and therapy2026

Effective Dose 90 of Programmed Intermittent Epidural Bolus Volume at Three Ropivacaine Concentrations with Dural Puncture Epidural for Labor Analgesia: A Randomized Sequential Allocation Study.

Linsen Sun, Xiaojuan Ding, Peng Zhai, Yan Jiang, Meijuan Sun, Xiangsheng Xiong

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Drug design, development and therapy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Linsen Sun *Department of Anesthesiology, Huai'an Hospital Affiliated to Yangzhou University (The Fifth People's Hospital of Huai'an), Huaian, People's Republic of China.
Xiaojuan Ding *Department of Anesthesiology, Huai'an Hospital Affiliated to Yangzhou University (The Fifth People's Hospital of Huai'an), Huaian, People's Republic of China.
Peng ZhaiDepartment of Anesthesiology, Huai'an Hospital Affiliated to Yangzhou University (The Fifth People's Hospital of Huai'an), Huaian, People's Republic of China.
Yan JiangDepartment of Anesthesiology, Huai'an Hospital Affiliated to Yangzhou University (The Fifth People's Hospital of Huai'an), Huaian, People's Republic of China.
Meijuan SunDepartment of Anesthesiology, Huai'an Hospital Affiliated to Yangzhou University (The Fifth People's Hospital of Huai'an), Huaian, People's Republic of China.
Xiangsheng XiongDepartment of Anesthesiology, Huai'an Hospital Affiliated to Yangzhou University (The Fifth People's Hospital of Huai'an), Huaian, People's Republic of China.ORCID 0009-0004-0233-2399

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: This study aimed to explore the ED90 of programmed intermittent epidural bolus (PIEB) volume for labor analgesia with different concentrations of ropivacaine when combining with dural puncture epidural (DPE) techniques. Methods: Ninety patients were randomized to three groups (n=30 each) to receive an initial 12-mL bolus of ropivacaine (0.075%, 0.1%, or 0.125%) with 0.3 μg/mL sufentanil. PIEB began at 60 min after the initial bolus, with 45-min intervals; the first patient in each group received 10 mL ropivacaine‑sufentanil solution, and subsequent volumes were adjusted by ± 2 mL via sequential allocation based on effective labor analgesia (no epidural bolus intervention administered). The primary and secondary outcomes were, respectively, the ED90 of PIEB volume at different ropivacaine concentrations for effective labor analgesia, and maternal analgesia quality and neonatal outcomes. Results: The ED90 of PIEB volume for achieving effective labor analgesia was 13.2 mL (95% CI, 11.9-14.5), 11.1 mL (95% CI, 10.0-12.2), and 9.4 mL (95% CI, 8.4-10.3) in the 0.075%, 0.1%, and 0.125% groups, respectively. No statistically significant differences in maternal analgesia quality and neonatal outcomes were identified among groups. Conclusion: When the combined DPE and PIEB technique is applied for effective labor analgesia, the ED90 of PIEB volume at concentrations of 0.075%, 0.1%, and 0.125% is 13.2 mL, 11.1 mL, and 9.4 mL respectively. Since higher concentration corresponds to a higher administered dose of ropivacaine, the ED90 of PIEB volume decreases as concentration increases.

Indexed as

Analgesia, EpiduralAnalgesia, ObstetricalAnesthetics, LocalRopivacaineAdultDose-Response Relationship, DrugFemaleHumansPregnancySpinal PunctureSufentanilAnesthetics, LocalRopivacaineSufentanilconcentrationdural puncture epidurallabor analgesiaprogrammed intermittent epidural bolusropivacaine

Identifiers

PMID42802743
PMCPMC13616149

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.