Evidence map›Paper›PMID 42801652›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026

Architected Load Paths Enable Stiffening and Motion Programming in Soft Pneumatic Actuators.

Jie Wang, Yuwen Wu, Yuze Zhang, Ye Wei, Yuting Ma, Yingxiang Liu, Kai Guo

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jie WangSchool of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei, People's of Republic China.
Yuwen WuSchool of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei, People's of Republic China.
Yuze ZhangSchool of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei, People's of Republic China.
Ye WeiSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, People's of Republic China.ORCID https://orcid.org/0009-0003-9889-3352
Yuting MaSchool of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei, People's of Republic China.
Yingxiang LiuState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, People's of Republic China.ORCID https://orcid.org/0000-0001-5684-9159
Kai GuoSchool of Biomedical Engineering (Suzhou), University of Science and Technology of China, Hefei, People's of Republic China.ORCID https://orcid.org/0000-0003-2071-6869

Funding

Innovative Key Project of Suzhou Institute of Biomedical Engineering and Technology, the Chinese Academy of Sciences CX20260103National Key R&D Program of China 2023YFB4706200Natural Science Foundation Project of Chongqing 2024NSCQ-MSX0007Science and Technology Development Plan Project of Jilin Province 20240305049YYScience and Technology Development Plan Project of Jilin Province 20260301020YYState Administration of Foreign Experts Affairs of China H20240225The pilot projects for fundamental research in Suzhou SSD2023014
6 · The paper itself

Abstract

Soft pneumatic robots exploit compliant chamber inflation to generate large and adaptive deformations, but increased pressure often produces ballooning rather than useful force or stiffness. This actuation-load-bearing decoupling limits their use in tasks that require both controlled motion and mechanical support. Here we report MARS (Monolithic Architected Reinforcement Strategy), a single-material soft pneumatic actuator that embeds beam-column-inspired load paths within an unchanged external envelope. Internal lateral beams guide bending and restrain lateral expansion, whereas radial columns tether the chamber wall and suppress ballooning. Together, these load paths redirect pneumatic deformation toward ordered structural engagement during actuation. Compared with an unconstrained baseline, MARS maintained its intended morphology up to 200 kPa and showed a 5.8-fold pressure-induced increase in lateral stiffness. At matched bending angles, it generated 8.4-fold higher tip force than the baseline. Selective removal of lateral beams further programmed the same monolithic template into continuous-bending, localized hinge-like-bending, and torsional variants. These variants enabled crawling-robot locomotion, load-bearing dexterous grasping, and EEG-guided wearable hand assistance. By coupling pneumatic actuation with internal load-path engagement, MARS establishes an architecture-guided strategy for mechanically supportive and motion-programmable soft pneumatic structures.

Indexed as

architected load pathsmonolithic soft actuatorsmotion programmingpressure‐induced stiffeningsoft pneumatic actuators

Identifiers

PMID42801652
PMCPMC13616343

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked