ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2026
Novel semi-automated system for multi-dimensional analysis of macular neovascularization: quantitative biomarkers and rule-based morphological categorization across OCTA platforms.
Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo develop and validate a novel semi-automated Python-based pipeline for multi-dimensional analysis of macular neovascularization (MNV) on optical coherence tomography angiography (OCTA) images. The system provides standardized biomarkers, rule-based morphological categorization, and morphology-derived interpretive labels. It also incorporates an automated morphological classification scheme to objectively distinguish active, mature quiescent, transitional, and arteriolarized states.
methodsWe developed an advanced image-processing pipeline incorporating hybrid multiscale vessel enhancement using Frangi/tubeness and Laplacian of Gaussian filters, hybrid binarization (LoG-Otsu and tubeness-Sauvola with small-particle removal), dynamic region-of-interest refinement, and boundary-branch exclusion. The system generates a Standardized Vascular Complexity Score, a Standardized Caliber Uniformity Score, and a Standardized Maturity Index on a 0-100 scale, and performs rule-based classification into Medusa, Seafan, Glomerular, Tree in bud, and Dead tree patterns using predefined percentile and trunk-pattern thresholds. Morphology-derived interpretive categories - Active pattern, Maturequiescentpattern, Transitional-pattern, and Arteriolarized pattern - were assigned using quantitative thresholds and published morphological criteria. A total of 112 MNV lesions acquired on three OCTA platforms (Zeiss PlexElite 6 × 6 mm, Zeiss CIRRUS AngioPlex HD 3 × 3 mm, and Optovue Solix 6 × 6 mm) were analyzed. Masked expert-automated morphological agreement was assessed in a stratified subset (n = 54). Inter-observer reproducibility was evaluated with three operators in 46 lesions using ICC(2,1), and same-operator intra-observer test-retest reproducibility was assessed as a supplement (n = 46). Between-stratum score differences were summarized using Kruskal-Wallis tests and ε² effect sizes with bootstrap 95% confidence intervals.
resultsRaw topological metrics differed substantially by device, precluding direct numerical comparison. Device-specific standardization using principal component analysis and piecewise-linear normalization yielded convergent standardized Complexity, Caliber Uniformity, and Maturity scores on a common 0-100 reporting scale across devices, with median values of approximately 50. Under this standardized framework, Complexity Score, Caliber Uniformity Score, and Maturity Index did not differ significantly across strata (Kruskal-Wallis p = 0.425, 0.572, and 0.582, respectively; ε² ≈ 0). Automated morphological classification identified the full spectrum of MNV subtypes across all platforms. Agreement with masked expert grading was modest to moderate, with an overall agreement of 57.4% and a quadratic weighted κ of 0.507. Inter-observer ICC(2,1) was good for lesion area (0.859), Complexity Score (0.807), and Standardized Caliber Uniformity Score (0.770), and moderate for the Maturity Index derived from the Caliber score (0.593).
conclusionThis system provides a transparent and robust platform for quantification and rule-based morphological reporting of MNV architecture across OCTA platforms, establishing a common framework for comparative analysis. Future outcome-linked and multi-center evaluations will be required to establish clinical utility. By integrating morphological patterns with quantitative biomarkers and automated classification, the system enables objective differentiation of active angiogenesis from mature remodeling.
Identifiers
42799766What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.