Evidence map›Paper›PMID 42798136›Full record

ArticleJournal of applied clinical medical physics2026

Maskless head and neck radiotherapy using surface-guided radiation therapy: initial clinical feasibility of real-time setup, intrafraction monitoring, and automatic beam-hold.

Adi Robinson, Shravan Kandula

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Adi RobinsonDepartment of Radiation Oncology, Medical Physics, AdventHealth Celebration, Celebration, Florida, USA.
Shravan KandulaDepartment of Radiation Oncology, Medical Physics, AdventHealth Celebration, Celebration, Florida, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThermoplastic immobilization remains standard for head and neck radiation therapy, but rigid face masks may produce clinically meaningful anxiety, claustrophobia, and treatment intolerance in some patients. Surface-guided radiation therapy (SGRT) provides non-ionizing surface setup guidance and continuous intrafraction motion monitoring, potentially enabling reduced-immobilization treatment approaches. PURPOSE: To describe and initially evaluate the clinical feasibility of a thermoplastic-maskless head and neck radiation therapy workflow using a posterior dorsal shell, SGRT-guided setup, cone-beam computed tomography (CBCT) verification, and real-time intrafraction monitoring with automatic beam-hold.

methodsTen patients with head and neck cancer were treated without a thermoplastic face mask. Patients were positioned in a posterior dorsal shell. Daily setup began with SGRT followed by CBCT verification and couch correction. During delivery, SGRT (AlignRT v6.3, Vision RT, London, UK) monitored head position in six degrees of freedom (6DoF); automatic beam-hold was triggered when translational displacement exceeded 2 mm or rotational displacement exceeded 2°. Post-treatment CBCT and SGRT log files were reviewed for every fraction to characterize residual displacement, threshold events, and repositioning. Intrafraction motion and residual displacement were summarized as medians with interquartile range (IQR).

resultsAcross 330 delivered fractions, sgrt-recorded intrafraction motion was small:: per-axis signed real-time deltas had a median [IQR] of 0.10 mm [-0.15, 0.30] translationally and 0.10° [-0.05, 0.20] rotationally. No fraction had a mean real-time delta exceeding the ± 2 mm/ ± 2° tolerance, and automatic beam-hold interruptions occurred in approximately 2% of fractions (7 of 330); no fraction was abandoned. Per-axis post-treatment CBCT residuals were -0.01 mm [-0.04, 0.05] translationally and 0.15° [-0.40, 0.55] rotationally. All patients completed the maskless course; 3 of 10 had previously declined or been unable to tolerate mask-based treatment, and all reported the maskless workflow to be well tolerated on an end-of-course questionnaire.

conclusionsA thermoplastic-maskless head and neck workflow using SGRT, CBCT verification, predefined beam-hold thresholds, and dorsal shell support was feasible in this initial 10-patient experience, maintaining small observed intrafraction motion while directly addressing mask intolerance. Larger prospective evaluation with validated patient-reported outcomes, dosimetric analysis, and multi-institutional QA is warranted.

Indexed as

Head and Neck NeoplasmsImmobilizationPatient PositioningRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedCone-Beam Computed TomographyDose Fractionation, RadiationFeasibility StudiesFemaleHumansMaleMovementOrgans at RiskPrognosisRadiotherapy DosageRadiotherapy, Intensity-Modulatedcone‐beam CThead and neck radiotherapyintrafraction motionmaskless immobilizationpatient comfortSGRTsurface‐guided radiation therapy

Identifiers

PMID42798136
PMCPMC13615301

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked