Fabrication of a Flexible PDMS/MWCNTs Composite Sensor Based on a Triboelectric Nanogenerator (Teng) and Its Application in Pulse Monitoring.
Article in Polymers, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
In view of the demand for wearable physiological monitoring, porous PDMS/MWCNTs composite films were fabricated via the sacrificial template method in this work. Output performance tests were carried out on films with different sacrificial particle sizes, film thicknesses, and multi-walled carbon nanotube (MWCNT) mass fractions. Scanning electron microscopy (SEM) was employed for structural morphology characterization. The optimal particle size, thickness, and doping ratio were confirmed to be 63 μm, 3 mm, and 9 wt%, respectively, and flexible sensor arrays based on triboelectric nanogenerators were further fabricated. In this paper, a complete signal conditioning system consisting of a flexible sensor array and a signal acquisition circuit (including a power supply unit, reset circuit, signal conditioning module, and core control chip) was designed to realize data transmission and upper computer display. Pulse signals from four volunteers were collected in five groups, respectively, for comparative analysis. Experimental results reveal that multiple sets of pulse data from the same subject show high consistency. Slight deviations within 0.38 V are merely caused by breathing and other subtle interference factors. These results verify that the prepared sensor possesses favorable sensitivity and repeatability.