Evidence map›Paper›PMID 42796968›Full record

ArticleNutrients2026

Comprehensive Comparison of Three Automated 25-Hydroxyvitamin D Immunoassays with a VDSCP Traceable LC-MS/MS Method Across Clinically Relevant Decision Thresholds.

Szilvia Racz, Luca Jozsa, Amrit Pal Bhattoa-Buzas, Emese Szmik, Edit Kalina, Sandor Barath, Dora Bencze, Etienne Cavalier, Harjit Pal Bhattoa

Abstract readComparative Study
In one paragraph

Article in Nutrients, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Szilvia RaczDepartment of Medical Imaging, Faculty of Medicine, Kalman Laki Doctoral School of the University of Debrecen, University of Debrecen, 4032 Debrecen, Hungary.ORCID 0009-0004-3222-8250
Luca JozsaDepartment of Laboratory Medicine, Faculty of Medicine, University of Debrecen, 4032 Debrecen, Hungary.
Amrit Pal Bhattoa-BuzasDepartment of Laboratory Medicine, Faculty of Medicine, University of Debrecen, 4032 Debrecen, Hungary.
Emese SzmikDepartment of Laboratory Medicine, Faculty of Medicine, University of Debrecen, 4032 Debrecen, Hungary.
Edit KalinaDepartment of Laboratory Medicine, Faculty of Medicine, University of Debrecen, 4032 Debrecen, Hungary.
Sandor BarathDepartment of Laboratory Medicine, Faculty of Medicine, University of Debrecen, 4032 Debrecen, Hungary.
Dora BenczeDepartment of Laboratory Medicine, Faculty of Medicine, University of Debrecen, 4032 Debrecen, Hungary.ORCID 0000-0002-8878-8175
Etienne CavalierDepartment of Clinical Chemistry, University of Liège, B-4000 Liège, Belgium.
Harjit Pal BhattoaDepartment of Laboratory Medicine, Faculty of Medicine, University of Debrecen, 4032 Debrecen, Hungary.ORCID 0000-0002-4909-0065

Funding

Beckman Coulter (United States)
6 · The paper itself

Abstract

BACKGROUND/

objectiveAccurate measurement of serum 25-hydroxyvitamin D (25OHD) is essential for the diagnosis and management of vitamin D deficiency. Although automated immunoassays are widely used in routine clinical practice, analytical variability between platforms may lead to inconsistent patient classification around clinically relevant decision thresholds. This study comprehensively compared three automated immunoassays (DiaSorin Liaison XL, Beckman Coulter DxI 9000, and Roche cobas e602) with a Vitamin D Standardization Certification Program (VDSCP)-traceable liquid chromatography-tandem mass spectrometry (LC-MS/MS) reference method.

methodsA total of 400 anonymized adult outpatient serum samples were prospectively collected and equally distributed across four predefined vitamin D concentration categories (<25, 25-49, 50-74, and ≥75 nmol/L). Samples were stored at -70 °C before simultaneous analysis on the three automated immunoassays and the reference LC-MS/MS platform. Method comparison included Deming regression, Bland-Altman analysis, and evaluation of diagnostic performance at clinically relevant thresholds (<25, <50, and <75 nmol/L). The effects of sample storage, vitamin D metabolites (C3-epi-25OHD

resultsSignificant analytical differences were observed between all immunoassays and LC-MS/MS. Roche cobas e602 consistently overestimated 25OHD concentrations, resulting in reduced sensitivity but excellent specificity and positive predictive value across all clinical thresholds. Beckman Coulter demonstrated the highest sensitivity for detecting vitamin D deficiency but generated more false-positive classifications, particularly at the <75 nmol/L threshold. DiaSorin Liaison XL achieved the best overall balance between sensitivity, specificity, accuracy, and agreement with LC-MS/MS, with Cohen's κ values ranging from 0.818 to 0.895 across decision thresholds. Higher concentrations of C3-epi-25OHD

conclusionsDespite ongoing international standardization efforts, clinically important differences remain among automated 25OHD immunoassays. Assay-specific analytical characteristics significantly influence patient classification around established decision thresholds. DiaSorin Liaison XL demonstrated the closest overall agreement with the reference LC-MS/MS method, whereas Beckman Coulter prioritized sensitivity and Roche specificity. These findings highlight the importance of method-aware interpretation of vitamin D results and support continued assay harmonization to improve comparability in routine clinical practice.

Indexed as

Liquid Chromatography-Mass SpectrometryTandem Mass SpectrometryVitamin DVitamin D DeficiencyAdultAutomationChromatography, LiquidFemaleHumansImmunoassayMaleMiddle AgedProspective StudiesReproducibility of ResultsSensitivity and Specificity25-hydroxyvitamin DVitamin D25-hydroxyvitamin DBeckman Coulter DxI 9000comparison studyDiaSorin Liaison XLLC-MS/MSRoche Cobas e602vitamin D metabolites

Identifiers

PMID42796968
PMCPMC13610336

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked