ArticleMicromachines2026
Asymmetric Flow Dynamics in a Pneumatically Actuated Polydimethylsiloxane (PDMS) Micropump: Numerical Simulation and Experimental Validation.
Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study presents a comprehensive numerical and experimental investigation on a pneumatically actuated polydimethylsiloxane (PDMS) micropump integrated with passive check valves (PCVs). Advanced three-dimensional (3D) fluid-structure interaction (FSI) simulations were conducted to capture the nonlinear large deformation of the membrane and elucidate the Newtonian flow dynamics. The maximum deformation calculated by the simulations was compared with the theoretical Timoshenko formula, demonstrating excellent agreement across the entire pressure range (3.0-100.0 kPa). The 3D FSI simulations revealed a considerable asymmetry in the flow dynamics between the suction and compression phases. Notably, at applied pressures exceeding 20.0 kPa, the discharge volume substantially outweighed the suction one. To characterize both the ideal and practical volumetric flow rates, curve-fitting analyses revealed that both the simulation and experimental data follow a consistent 1/3-power-law relationship with respect to the applied pressure. Experimentally, the micropump achieved a maximum volumetric flow rate of 2.6 mL/min at 70.0 kPa and 12.0 Hz. Furthermore, the micropump demonstrated a peak pumping efficiency of 56.95% at 35.0 kPa and 10.0 Hz relative to the ideal numerical baseline. By bridging idealized numerical bounds with experimental realities, this validated framework offers a robust predictive tool for optimizing flow asymmetry and pumping efficiency in advanced microfluidic systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.