Evidence map›Paper›PMID 42796147›Full record

ArticleMicromachines2026

Asymmetric Flow Dynamics in a Pneumatically Actuated Polydimethylsiloxane (PDMS) Micropump: Numerical Simulation and Experimental Validation.

Pei-Pei Hsu, Jr-Lung Lin

Abstract read
In one paragraph

Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Pei-Pei HsuDepartment of Mechanical and Automation Engineering, I-Shou University, Kaohsiung 84001, Taiwan.
Jr-Lung LinDepartment of Mechanical and Automation Engineering, I-Shou University, Kaohsiung 84001, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study presents a comprehensive numerical and experimental investigation on a pneumatically actuated polydimethylsiloxane (PDMS) micropump integrated with passive check valves (PCVs). Advanced three-dimensional (3D) fluid-structure interaction (FSI) simulations were conducted to capture the nonlinear large deformation of the membrane and elucidate the Newtonian flow dynamics. The maximum deformation calculated by the simulations was compared with the theoretical Timoshenko formula, demonstrating excellent agreement across the entire pressure range (3.0-100.0 kPa). The 3D FSI simulations revealed a considerable asymmetry in the flow dynamics between the suction and compression phases. Notably, at applied pressures exceeding 20.0 kPa, the discharge volume substantially outweighed the suction one. To characterize both the ideal and practical volumetric flow rates, curve-fitting analyses revealed that both the simulation and experimental data follow a consistent 1/3-power-law relationship with respect to the applied pressure. Experimentally, the micropump achieved a maximum volumetric flow rate of 2.6 mL/min at 70.0 kPa and 12.0 Hz. Furthermore, the micropump demonstrated a peak pumping efficiency of 56.95% at 35.0 kPa and 10.0 Hz relative to the ideal numerical baseline. By bridging idealized numerical bounds with experimental realities, this validated framework offers a robust predictive tool for optimizing flow asymmetry and pumping efficiency in advanced microfluidic systems.

Indexed as

asymmetric flow dynamicsfluid–structure interactionlarger deformationmicropumppumping efficiency

Identifiers

PMID42796147
PMCPMC13609855

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.