Evidence map›Paper›PMID 42796114›Full record

ArticleMicromachines2026

Arrayed Micropillar Ionic Film Iontronic Flexible Pressure Sensor and Its Wearable Sensing Applications.

Wenzhen Liang, Xiaodong Huang

Abstract read
In one paragraph

Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Wenzhen LiangSchool of Automation and Information Technology, Guangdong Polytechnic of Water Resources and Electric Engineering, Guangzhou 510635, China.
Xiaodong HuangDepartment of Intelligent and Information Engineering, Taiyuan University, Taiyuan 030051, China.ORCID 0000-0003-2018-8664

Funding

2025 Annual Guangdong Provincial Ordinary University Innovation Team Project 2025KCXTD080
6 · The paper itself

Abstract

Flexible pressure sensors serve as core sensing components for wearable health monitoring systems, electronic skins for soft robots, and flexible human-machine interaction devices. Benefiting from the interfacial electric double-layer polarization effect, iontronic sensing delivers far higher pressure response sensitivity than conventional parallel-plate capacitive sensors, endowing it with distinctive advantages in the detection of weak physiological signals. Nevertheless, current dense ionic thin-film dielectric layers suffer from limited deformation space under compression and poor low-pressure sensing capability. Mainstream high-precision micropillar arrays are fabricated via photolithography, 3D printing, and metal etching molds, which require costly equipment and complicated fabrication procedures, making large-area mass production unfeasible. Random frosted concave-convex microstructures feature disordered dimensions, leading to severe device hysteresis and narrow linear ranges, which fail to achieve ultrahigh sensitivity alongside a wide pressure detection range simultaneously. To address the aforementioned multiple bottlenecks, this paper proposes a low-cost resin template replication process to fabricate TPU-based ionic thin-film dielectric layers with ordered micropillar array microstructures. Combined with inkjet-printed silver conductive PI flexible electrodes, an iontronic flexible pressure sensor with a sandwich layered structure is constructed. Multi-dimensional investigations including microscopic morphology characterization, electromechanical sensing performance calibration, and human wearable application tests are systematically implemented to thoroughly elucidate the synergistic enhancement mechanism of the arrayed micropillars. Test results demonstrate that the effective pressure detection range of the sensor spans 0-1038 kPa, accommodating ultra-low pressures such as pulse signals as well as medium-to-high-pressure loads including joint bending. The sensitivity reaches 23.27 kPa

Indexed as

array micro-pillarselectronic skinionic filmiontronic flexible pressure sensorTPU elastic matrix

Identifiers

PMID42796114
PMCPMC13608937

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.