ArticleBioengineering (Basel, Switzerland)2026
Computational and Experimental Evaluation of a Flow-Conditioning Anastomotic Device for Arteriovenous Fistula Maturation.
Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The arteriovenous fistula (AVF) is the preferred method of vascular access for hemodialysis; however, 30-50% of AVFs undergo primary maturation failure and are unsuitable for clinical use. As disturbed hemodynamics initiate endothelial injury and intimal hyperplasia, we designed an endovascular flow-conditioning anastomotic device (FCAD) to directly improve AVF hemodynamics and protect the anastomotic region. Using computational fluid dynamics, we characterized the flow field and wall shear stress (WSS) profiles in idealized AVF models with and without the FCAD. Incorporation of the FCAD into a brachiocephalic AVF model reduced regions of oscillatory WSS and generated a symmetrical flow profile in the draining vein compared to a reference AVF. Parametric studies identified an FCAD geometry with a tab angle, height, and aspect ratio of 30°, 0.1 diameters, and 1.0 that increased time-averaged WSS along the inner venous wall and achieved a physiological WSS (1-3 Pa) without inducing regions of oscillatory flow throughout the cardiac cycle. Similar findings were observed with an in vitro model using particle image velocimetry. This study demonstrates the feasibility of the FCAD to normalize venous flow and WSS while imposing minimal resistance to blood flow. Restoring physiological WSS levels on the venous wall may help preserve endothelial function and improve AVF maturation.