Evidence map›Paper›PMID 42791871›Full record

ReviewBioengineering (Basel, Switzerland)2026

The Standardization and Comparability Gap in Evaluating Antibacterial Surfaces for Load-Bearing Orthopedic Implants: A Critical Review.

Il-Hoon Kwak, Hyunsuk Choi

Abstract readReview
In one paragraph

Review in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Il-Hoon KwakDepartment of Orthopedic Surgery, Kwak Hospital, Daegu 41919, Republic of Korea.
Hyunsuk ChoiDepartment of Dentistry and Prosthodontics, Daegu Catholic University School of Medicine, Daegu 42472, Republic of Korea.ORCID 0000-0002-0381-3870

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Periprosthetic joint infection is among the most serious complications of joint replacement, and the implant surface, where infection begins, is a rational prevention target. Antibacterial titanium surfaces act by releasing an agent, by contact killing, or by resisting adhesion. Yet the field cannot readily tell which method performs best, because efficacy is evaluated with methods that differ at every level and are rarely comparable: the same surface can read as highly effective under one assay and inactive under another, so the test rather than the material decides the verdict. This review asks where comparability is lost and what would restore it, for permanent load-bearing arthroplasty implants. We dissect the gap across in vitro assays, durability testing, surface characterization, in vivo models, clinical infection definitions, and regulatory expectations and ask whether the antibacterial-osseointegration trade-off is assessed coherently. We then propose a ten-item, stage-stratified minimum-reporting checklist and test it retrospectively on thirteen open-access studies. No study reported every item required at its stage; none related antibacterial dose to a stated cytotoxicity threshold; and studies fell short at different tiers, so their reported efficacies are not commensurable. The checklist is offered as a testable starting point for multi-stakeholder consensus, not a finished standard.

Indexed as

antibacterial coatingbiofilmevaluation methodologyosseointegrationperiprosthetic joint infectionstandardizationsurface modificationtitanium implant

Identifiers

PMID42791871
PMCPMC13603435

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.