ArticleBioengineering (Basel, Switzerland)2026
Effect of Axial and Coronal Malalignment on Polyethylene Stresses in Lumbosacral Total Joint Replacement: A Finite Element Study.
Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The purpose of this study was to analyze the sensitivity of polyethylene stresses and strains, as proxies for wear and surface damage, to coronal and axial misalignment for a novel lumbar total joint replacement (LTJR) implanted at L5-S1. We hypothesized that these stresses and strains would remain below the levels associated with worst-case impingement in a spine wear simulator. A finite element model (FEM) of the L4-S1 spine was developed using CT-based anatomy from a representative Investigational Device Exemption study patient. An appropriately sized LTJR was virtually implanted at L5-S1 in a standardized baseline orientation, and component positioning was altered to achieve eight independent misalignment scenarios, spanning axial convergence angle, anterior-posterior offset, and coronal tilt. Physiologic forward-bending loads were applied, and polyethylene contact pressure, von Mises stress, and effective strain were recorded. Peak values for the baseline scenario were 35.0 MPa, 19.9 MPa, and 4.8%, respectively. Convergence angle and anterior-posterior offset had minimal effect, whereas coronal tilt produced the largest changes. Contact pressure and von Mises stress varied by <20% due to misalignment, whereas effective strain was more sensitive, increasing from 4.8% at baseline to 9.9% with 20 degrees of coronal tilt. All values were comparable to prior L4-L5 findings and remained well below impingement levels. Within the bounds of reasonable misalignment, the device maintained bearing congruency and did not approach conditions associated with accelerated wear.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.