In one paragraph

Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jesús David RamírezProgram of Biomedical Engineering, Antonio Nariño University, Popayán, Colombia.
Nathalia ToroProgram of Biomedical Engineering, Antonio Nariño University, Popayán, Colombia.
Juan Manuel CampoProgram of Biomedical Engineering, Antonio Nariño University, Popayán, Colombia.
Guido Gómez-PeñaProgram of Biomedical Engineering, Antonio Nariño University, Popayán, Colombia.
Julián Antonio Villamarín-MuñozProgram of Biomedical Engineering, Antonio Nariño University, Popayán, Colombia.ORCID http://orcid.org/0000-0001-8383-8340
Jaime A Mosquera-SánchezDepartment of Mechanical Engineering, São Carlos School of Engineering, University of São Paulo (USP), São Carlos, Brazil. jamosquera@usp.br.ORCID http://orcid.org/0000-0002-6032-4993

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiovascular diseases remain the leading cause of mortality worldwide, with ischaemic heart disease the leading contributor and acute myocardial infarction accounting for the majority of ischaemic heart disease deaths. This study presents the development and technical validation of a low-cost, integrated wearable system for multi-parameter cardiorespiratory monitoring designed to support heart-attack detection algorithms. The system comprises two devices: a wristband incorporating a MAX30105 photoplethysmography sensor for cardiac pulse-wave and SpO[Formula: see text] acquisition, and a chest band featuring novel optical respiratory detection and an MPU6050 inertial measurement unit for respiratory rate and movement monitoring. Both devices use ESP32-C3 microcontrollers with Bluetooth Low Energy connectivity to a custom mobile application enabling real-time visualization and cloud-based storage. Validation was conducted against clinical-grade reference equipment (ADInstruments physiograph and EDAN iM8 monitor) in 43 healthy volunteers, yielding 50 acquisitions: 30 at rest and 20 post-physical activity. This is a technical feasibility study in healthy young volunteers; validation in clinical populations remains future work. Heart rate showed the closest agreement with the reference (percentage error ±1.94%, [Formula: see text] post-activity; limits of agreement [Formula: see text] to 4.21 BPM), followed by respiratory rate (±3.47%, [Formula: see text]). SpO[Formula: see text] error remained within tolerance (1.64% at rest, 2.98% post-activity) but showed weak correlation with the reference owing to range restriction in a healthy cohort, and is not yet suitable for applications requiring absolute saturation values. This study demonstrates that a low-cost, multi-sensor wearable system can achieve accuracy meeting the prespecified feasibility criterion ([Formula: see text]5% error) in a healthy young cohort, establishing technical feasibility as a prerequisite to validation in the cardiovascular patient populations for which the system is ultimately intended.

Indexed as

Cardiorespiratory monitoringHeart rate variabilityMobile healthPhotoplethysmographyWearable devices

Identifiers