Evidence map›Paper›PMID 42787423›Full record

ArticleFrontiers in public health2026

Performance evaluation of vacuum blood collection tubes in multicenter clinical laboratories: a real-world study from Southwest China.

Changrui Sun, Chunbao Xie, Xuelong Xie, Li Li, Jian Xu, Jing Ren, Dan Zheng, Juan Du, Zaixiang Xie, Huan Ding and 3 more

Abstract readMulticenter Study
In one paragraph

Article in Frontiers in public health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Changrui Sun *Department of Laboratory Medicine, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, China.
Chunbao Xie *Department of Laboratory Medicine, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, China.
Xuelong Xie *Department of Clinical Laboratory, The Second People's Hospital of Yibin·West China Yibin Hospital, Sichuan University, Yibin, China.
Li LiDepartment of Clinical Laboratory, Chinese and Western Medicine Hospital of Panzhihua, Panzhihua, China.
Jian XuDepartment of Medical Laboratory, Dazhou Central Hospital, Dazhou, China.
Jing RenDepartment of Hospital Laboratory, Guangyuan Central Hospital, Guangyuan, Sichuan, China.
Dan ZhengCenter of Clinical Laboratory Medicine, Guanghan People's Hospital, Deyang, Sichuan, China.
Juan DuDepartment of Laboratory Medicine, People's Hospital of Ganzi Tibetan Autonomous Prefecture, Kangding, Sichuan, China.
Zaixiang XieDepartment of Clinical Laboratory, Qianjiang District Hospital of Traditional Chinese Medicine, Chongqing, China.
Huan DingDepartment of Clinical Laboratory, Zhongxian People's Hospital of Chongqing, Chongqing, China.
Lan HuangDepartment of Clinical Laboratory, Chinese and Western Medicine Hospital of Panzhihua, Panzhihua, China.
Bing ZhangDepartment of Laboratory Medicine, Nanchong Central Hospital, Nanchong, Sichuan, China.
Yi HuangDepartment of Laboratory Medicine, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Pre-analytical errors account for 60-70% of total laboratory errors, with vacuum blood collection tube quality being a key contributor. Southwest China's complex terrain (plain/plateau areas) and demand for inter-hospital test result mutual recognition highlight the need for region-specific performance data. Methods: This multicenter real-world study evaluated 10 blood collection tube brands across 10 hospitals (plain/plateau areas) in Sichuan-Chongqing. Nine physical performance indicators (appearance, tube strength, fill volume, stopper shedding, hemolysis, fibrin adhesion, separation gel integrity, anticoagulation efficacy, and tube-body integrity) were verified against BD tubes, following CLSI GP34-A2 and WS/T 224-2018, with additional clinical consistency analyses for hematological, coagulation, and biochemical parameters. Statistical analysis included linear regression ( Results: Widespread performance deficiencies were observed. At the hospital level, fill-volume non-compliance affected 78.3% (7/9) of plain-area hospitals, while at the tube-batch level, 20.0% (1/5) of batches failed at the single plateau site. For stopper shedding, 83.3% (25/30) of tube batches across all sites exceeded the acceptable threshold, corresponding to 80% (8/10) of hospitals having at least one non-compliant tube type. Tube appearance, structural strength, and separation gel integrity were universally compliant across all sites. Conclusion: Southwest China's routinely used vacuum blood collection tubes exhibit critical performance gaps, particularly in fill-volume accuracy and stopper integrity. Routine verification of high-risk indicators, site-adaptive batch-specific verification for high-altitude facilities, and manufacturing improvements (e.g., stopper material optimization) are recommended. This study provides quality benchmarks for regional test result mutual recognition and pre-analytical quality improvement.

Indexed as

Blood Specimen CollectionLaboratories, ClinicalChinaHumansVacuummulticenter studyperformance evaluationreal-world studySouthwest Chinavacuum blood collection tubes

Identifiers

PMID42787423
PMCPMC13601300

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.