Evidence map›Paper›PMID 42787061›Full record

ReviewFrontiers in robotics and AI2026

Robot-assisted spinal surgery: technological maturity, clinical evidence, and future directions.

Xue Li, Shilong Li, Minfei Wu, Jianhang Jiao, Tong Yu

Abstract readReview
In one paragraph

Review in Frontiers in robotics and AI, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xue LiDepartment of Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, Jilin, China.
Shilong LiDepartment of Orthopedic and Soft Tissue Surgery, Jilin Cancer Hospital, Changchun, Jilin, China.
Minfei WuDepartment of Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, Jilin, China.
Jianhang JiaoDepartment of Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, Jilin, China.
Tong YuDepartment of Orthopaedic Medical Center, The Second Norman Bethune Hospital of Jilin University, Changchun, Jilin, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Robot-assisted spinal surgery has evolved from bone-mounted trajectory guidance to integrated navigation and, in selected research systems, constrained task execution. This evolution has been accompanied by rapid commercial and academic activity, but regulatory status, technical capability, and clinical effectiveness are often conflated. Such conflation can overstate both the maturity of emerging platforms and the certainty of their patient-level benefits. This structured narrative review was developed from a reproducible PubMed search, targeted citation chasing, Crossref metadata verification, and model-specific regulatory checks. Evidence was organized by source class and by outcome domain rather than by manufacturer chronology alone. Established platforms were separated from early clinical and preclinical systems, and regulatory clearance or registration was treated as distinct from evidence of comparative effectiveness. The most consistent evidence concerns pedicle-screw placement accuracy. Comparative studies and evidence syntheses generally favor robot-assisted placement over freehand or fluoroscopy-guided techniques, although the magnitude and consistency of benefit vary by platform, comparator, grading system, and surgeon experience. Radiation exposure may be reduced in some workflows, but acquisition protocols and reporting units are heterogeneous. Evidence for operative time, complications, revision surgery, patient-reported outcomes, and cost-effectiveness remains inconsistent or sparse. The principal contribution of this review is an evidence-maturity framework that links each technical capability to the strongest available clinical evidence and explicitly separates premarket regulatory decisions from claims of clinical superiority. Robot-assisted systems should currently be understood as surgeon-controlled enabling technologies. Future progress will depend less on adding degrees of freedom than on demonstrating reproducible patient benefit, safe task autonomy, interoperable data pipelines, and value across health-care settings.

Indexed as

clinical evidencepedicle screw placementrobot-assisted spinal surgeryspinal navigationsurgical robotics

Identifiers

PMID42787061
PMCPMC13600806

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.