Evidence map›Paper›PMID 42786272›Full record

ArticleCardiovascular intervention and therapeutics2026

TAVI-TEC: an AI-based tool for procedural planning of transcatheter aortic valve implantation.

Alessandra Zerillo, Stefano Cannata, Diego Bellavia, Daniele Ciriello, Simone Manini, Salvatore Pasta, Caterina Gandolfo

Abstract read
PubMed Publisher
In one paragraph

Article in Cardiovascular intervention and therapeutics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alessandra ZerilloDepartment of Research, IRCCS-ISMETT, Palermo, Italy.
Stefano CannataDepartment for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, IRCCS-ISMETT, Palermo, Italy.
Diego BellaviaDepartment of Research, IRCCS-ISMETT, Palermo, Italy.
Daniele CirielloDICOM Vision, Dalmine, Italy.
Simone ManiniD/Vision Lab, Dalmine, Italy.
Salvatore PastaDepartment of Research, IRCCS-ISMETT, Palermo, Italy. salvatore.pasta@unipa.it.ORCID http://orcid.org/0000-0002-4841-2560
Caterina GandolfoDepartment for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, IRCCS-ISMETT, Palermo, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is becoming essential in clinical practice. This study presents TAVI-TEC, a fully automated artificial intelligence-based framework integrated into a web-based DICOM viewer for routine preoperative TAVI planning. Pre-procedural CTA scans from patients undergoing TAVI with SAPIEN 3 Ultra (S3U) prostheses were processed using a fully automated pipeline. Deep learning-based segmentation of cardiovascular structures, calcification detection, centerline extraction, landmark identification, and annular plane definition was implemented to quantify key annular and aortic root measurements and color-coded maps of lumen reduction and vessel diameter for vascular access. A multilayer perceptron classifier was trained to predict prosthesis size prior to the TAVI procedure. Results revealed that TAVI-TEC enabled pre-procedural measurements in approximately 2-6 min. Strong agreement with clinician-derived measurements was observed for annular area (coefficient of concordance, CCC = 0.934; interclass correlation coefficient, ICC = 0.935; R² = 0.881) and perimeter (CCC = 0.909; ICC = 0.909; R² = 0.854). The valve-size prediction model achieved a classification accuracy of 77.1% (95% CI: 70.1-83.9%) with the clinically selected and implanted valve size, with most discordances occurring between adjacent prosthesis sizes. These findings support the technical feasibility and promising initial performance of TAVI-TEC. Prospective multicenter and external validation, including additional valve platforms, will be required before routine clinical implementation and before its effects on operator variability and clinical workflow can be established.

Indexed as

Aortic stenosisArtificial intelligenceComputed tomography angiographyTranscatheter aortic valve implantationValve sizingVascular access

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.