Effect of Connection Geometry and Cantilever Length on the Mechanical Behavior of Ti6Al4V and PEEK Bar-Supported Implant Prostheses with Angled Abutments.
Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
Abstract
Angled abutments and cantilever extensions in bar-supported full-arch implant prostheses may generate bending moments and localized stress concentrations within prosthetic components and peri-implant bone. Implant-supported rehabilitation becomes biomechanically more demanding in completely edentulous patients with posterior bone resorption. Therefore, understanding how connection geometry, cantilever length, and framework material influence prosthetic design is important. In this study, a three-dimensional mandibular model generated from CT data was used to compare conventional and spherical abutment-bar connection designs in All-on-Four prostheses with 30° angled posterior abutments. Cantilever lengths of 8, 10, and 12 mm were evaluated, and Ti6Al4V Grade 5 and PEEK were assigned as alternative bar prosthesis materials. Finite element analyses were performed in ANSYS Workbench, and von Mises stress distributions were evaluated in the bar prosthesis, prosthetic screws, abutments, implants, and surrounding cortical and trabecular bone. The results showed that increasing cantilever length increased stress levels in prosthetic components and bone tissues. The spherical connection design generally reduced stresses in the most critical distal components compared with the conventional design; however, this reduction was not uniform for all components, particularly in the PEEK models. The highest stress value was observed in the posterior angled abutment of the PC-12 model with a PEEK bar prosthesis (1592.2 MPa). Among the implant components, the lowest stress was observed in the anterior implant of the TS-8 model (27.99 MPa). In contrast, the lowest bone stress was recorded in the anterior trabecular bone capsule of the PC-8 model. These findings indicate that cantilever length and connection geometry are critical parameters in designing full-arch implant prostheses. At the same time, the use of PEEK as a bar material should be interpreted with caution under extended-cantilever conditions.