Evidence map›Paper›PMID 42783679›Full record

ArticleJournal of functional biomaterials2026

Thermo-Mechanical Characterization of Innovative Side-Rounded Superelastic CuNiTi Orthodontic Wires.

Michele Basilicata, Giovanni Bruno, Gennaro Salvatore Ponticelli, Patrizio Bollero, Raffaella Docimo, Alessandra Fava, Stefano Guarino, Roberto Montanari, Alessandra Palombi, Alfio Scuderi and 1 more

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Michele BasilicataDepartment of Experimental Medicine and Surgery, UOSD Special Care Dentistry, University of Rome Tor Vergata, 00133 Rome, Italy.
Giovanni BrunoDepartment of Neuroscience, University of Padua, 35122 Padova, Italy.ORCID 0000-0003-2900-7196
Gennaro Salvatore PonticelliDepartment of Engineering, University Niccolò Cusano, 00166 Rome, Italy.ORCID 0000-0001-7984-4334
Patrizio BolleroDepartment of Systems Medicine, UOSD Special Care Dentistry, University of Rome Tor Vergata, 00133 Rome, Italy.
Raffaella DocimoDepartment of Surgical Sciences, UOSD Pediatric Dentistry, University of Rome Tor Vergata, 00133 Rome, Italy.
Alessandra FavaDepartment for Sustainability, Research Centre of Casaccia, National Agency for New Technologies, Energy and Sustainable Economic Development, Via Anguillarese 301, Santa Maria di Galeria, 00123 Rome, Italy.ORCID 0000-0001-6997-4573
Stefano GuarinoDepartment of Engineering, University Niccolò Cusano, 00166 Rome, Italy.ORCID 0000-0001-5474-0440
Roberto MontanariDepartment of Industrial Engineering, University of Rome Tor Vergata, 00133 Rome, Italy.ORCID 0000-0001-7791-4431
Alessandra PalombiDepartment of Industrial Engineering, University of Rome Tor Vergata, 00133 Rome, Italy.ORCID 0009-0005-2622-4381
Alfio ScuderiDepartment of Engineering, University Niccolò Cusano, 00166 Rome, Italy.ORCID 0009-0009-6762-2254
Alessandra VaroneDepartment of Industrial Engineering, University of Rome Tor Vergata, 00133 Rome, Italy.ORCID 0000-0002-6034-859X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study evaluates the thermal and mechanical behavior of innovative copper-nickel-titanium (CuNiTi) rectangular orthodontic wires featuring rounded edges across two different sizes for clinical applications. Differential scanning calorimetry (DSC) was performed from -20 °C to +80 °C to determine phase transformation temperatures according to ASTM F2004. Three-point bending tests were conducted in accordance with ISO 15841 to evaluate unloading forces (at 3, 2, 1, and 0.5 mm deflections) and permanent residual deflection at 23 °C (room temperature) and 37 °C (oral environment). DSC analysis revealed a single-stage phase transformation within the range 10 °C to 27 °C, indicating near-superelastic behavior at room temperature. Mechanical testing demonstrated reproducible force-deflection profiles and low permanent deformation. At body temperature (37 °C), unloading forces in the 2.0-0.5 mm activation range averaged between 1.9 N and 3.2 N depending on wire cross-section. In conclusion, the evaluated CuNiTi wires provide consistent force delivery during unloading at physiological temperature, offering suitable mechanical properties for orthodontic alignment applications.

Indexed as

CuNiTi shape memory alloydifferential scanning calorimetryorthodontic wiressuperelasticitythree-point bending

Identifiers

PMID42783679
PMCPMC13607737

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.