Evidence map›Paper›PMID 42781178›Full record

ArticleJournal of cardiovascular echography

From Presyncope to Recovery: Echocardiography-guided Transcatheter Aortic Valve Implantation for Severe Bicuspid Aortic Stenosis.

S Fildzah Dini Atikah, Achmad Lefi, Ovin Nada Saputri, Dian Paramita Kartikasari, Ratih Rahmanyati Pasah, Irawati Hajar Kikuko, Yudi Her Oktaviono

Abstract readCase Reports
In one paragraph

Article in Journal of cardiovascular echography. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

S Fildzah Dini AtikahDepartment of Cardiology and Vascular Medicine, Faculty of Medicine, Dr. Soetomo General Hospital, Universitas Airlangga, Surabaya, Indonesia.
Achmad LefiDepartment of Cardiology and Vascular Medicine, Faculty of Medicine, Dr. Soetomo General Hospital, Universitas Airlangga, Surabaya, Indonesia.
Ovin Nada SaputriDepartment of Cardiology and Vascular Medicine, Faculty of Medicine, Dr. Soetomo General Hospital, Universitas Airlangga, Surabaya, Indonesia.
Dian Paramita KartikasariDepartment of Cardiology and Vascular Medicine, Faculty of Medicine, Dr. Soetomo General Hospital, Universitas Airlangga, Surabaya, Indonesia.
Ratih Rahmanyati PasahDepartment of Cardiology and Vascular Medicine, Faculty of Medicine, Dr. Soetomo General Hospital, Universitas Airlangga, Surabaya, Indonesia.
Irawati Hajar KikukoDepartment of Cardiology and Vascular Medicine, Faculty of Medicine, Dr. Soetomo General Hospital, Universitas Airlangga, Surabaya, Indonesia.
Yudi Her OktavionoDepartment of Cardiology and Vascular Medicine, Faculty of Medicine, Dr. Soetomo General Hospital, Universitas Airlangga, Surabaya, Indonesia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Bicuspid aortic valve (AV) is the most common congenital cardiac valvular anomaly and often progresses to severe calcific aortic stenosis (AS). Although surgical AV replacement has been the conventional treatment, transcatheter AV implantation (TAVI) is emerging as a viable alternative, especially in patients with high surgical risk or complex anatomy. This case report demonstrates the crucial role of echocardiography in the management of TAVI in a patient with bicuspid AS. A 66-year-old male with a 3-year history of palpitations and recurrent presyncope underwent a comprehensive evaluation for suspected AV disease. Transthoracic echocardiography (TTE) revealed severe bicuspid AS with preserved left ventricular function. Coronary angiography and computed tomography angiography were performed for anatomical and procedural assessment, confirming suitability for TAVI. The procedure was conducted through a transfemoral approach using a 24-mm self-expanding bioprosthetic valve under echocardiographic guidance. TEE provided real-time imaging during valve deployment, while serial TTE was used for postprocedural and follow-up evaluations at 1 and 6 months to assess valve function and complications. This case underscores the central role of echocardiography in the comprehensive management of TAVI for bicuspid AS, from patient selection and intraprocedural guidance to postimplantation monitoring, ultimately optimizing clinical outcomes.

Indexed as

Aortic stenosisbicuspid aortic valveechocardiographystructural heart diseasetranscatheter aortic valve implantation

Identifiers

PMID42781178
PMCPMC13600636

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.