ArticleJournal of cardiothoracic surgery2026
The trap device retrieves the detached stent that is floating within the ascending aorta.
Article in Journal of cardiothoracic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCoronary stent dislodgement is a relatively infrequent iatrogenic complication associated with percutaneous coronary intervention (PCI). It can result in severe outcomes, including vascular embolism, coronary rupture, malignant arrhythmia, and even death. We reported a patient who previously underwent stent implantation in the left anterior descending artery (LAD) and required a second-stage surgery. During the insertion of a new stent into the left circumflex artery (LCX), the guidewire passed through the mesh of the original stent. This caused the new stent to pull and deform the original stent during advancement. Consequently, the new stent dislodged, and the two stents intertwined and floated in the aorta. Eventually, the two stents were successfully removed using a stent snare, and a new stent was reimplanted in the LAD, thereby avoiding the risk of the dislodged stent falling into other arteries and causing embolism. In our case, the characteristic of the original stent protruding into the left main coronary artery (LM) and the surgeon's failure to promptly confirm the position of the guidewire were the main causes of this incident, which provide valuable experience for future interventional surgeries. DISCUSSION: When the original stent located at the bifurcation of the blood vessel is passed through, preoperative assessment of the spatial relationship between the blood vessels, careful confirmation of the position of the guidewire, and timely analysis of whether stent dislodgement, traction, etc. occurs when advancement is impeded are critical to procedural success.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.