Evidence map›Paper›PMID 42778677›Full record

ArticleInternational journal of biometeorology2026

Elevation-dependent classification of outdoor thermal stress in a tropical Andean country: a case study of Colombia.

Cristian Mejía-Parada, Viviana Mora-Ruiz, Luis Otero-Meneses, Harvey Mieles, Jonathan Soto-Paz, Brayan A Parra-Orobio

Abstract read
In one paragraph

Article in International journal of biometeorology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Cristian Mejía-ParadaBarcelona School of Architecture (ETSAB), Universitat Politècnica de Catalunya - BarcelonaTech (UPC), Av. Diagonal 649-651, Barcelona, 08028, Spain. cristian.andres.mejia@upc.edu.
Viviana Mora-RuizDepartamento de Ingeniería Civil: Construcción, Canales y Puertos, E.T.S de Ingenieros de Caminos, Universidad Politécnica de Madrid, c/Profesor Aranguren, s/n, Madrid, 28040, Spain.
Luis Otero-MenesesFaculty of Engineering. AVR Research Group, Universidad de Investigación y Desarrollo, Calle 9 # 23-55, Bucaramanga, Santander, Colombia.
Harvey MielesFaculty of Engineering. AVR Research Group, Universidad de Investigación y Desarrollo, Calle 9 # 23-55, Bucaramanga, Santander, Colombia.
Jonathan Soto-PazFacultad de Ingeniería, Grupo de investigación en logística y analítica para una sociedad sostenible-LASSOS, Facultad de Ingeniería, Universidad del Valle, Calle 13 # 100-00, Cali, Colombia.
Brayan A Parra-OrobioFacultad de Ingeniería Civil, Grupo de Investigación en Ciencias e Ingeniería en Sistemas Ambientales-GCISA-TSEJK, Universidad del Cauca, Popayán, 190002, Colombia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Outdoor thermal comfort in tropical mountain countries is shaped by air temperature, humidity, wind, solar radiation and topography, with elevation strongly controlling thermal stress (TS). This study evaluates how elevation modulates outdoor TS in Colombia and proposes an elevation-based thermal stress level (TSL) classification. Typical Meteorological Year (TMY) datasets from the National Solar Radiation Database (NSRDB) were used to compute four thermal indices: Universal Thermal Climate Index (UTCI), Effective Temperature (ETv), Thermo-Hygrometric Index (THI) and the national heat index (IDEAM-HI) for 69,874 locations. For each index, linear and second-degree polynomial regressions between elevation and the annual maximum, mean and minimum values were fitted and assessed using RMSE and R². Polynomial models generally outperformed linear models, particularly for UTCI, explaining up to 96% of the variance in the annual maximum values. The resulting functions were used to derive elevation ranges for different TSL and to produce a TS classification and map. Large lowland areas are predominantly classified within warm and very hot stress conditions, whereas thermally comfortable conditions are mostly restricted to intermediate elevations between 1,080 and 2,050 m.a.s.l. In addition, an exploratory hourly UTCI assessment was performed for four cities using TMY data for representative urban configurations. The urban results qualitatively confirm the elevation-based TS classes and show how diurnal cycles and intra-urban differences modulate TS within each elevation band. The proposed framework provides a climatological, screening-level multi-scale reference for typical outdoor TS in Colombia, enabling baseline spatial prioritization for heat-health risk assessment, climate-resilient planning and comparative assessment planning in tropical Andean regions.

Indexed as

AltitudeHeat Stress DisordersColombiaHot TemperatureTemperatureThermal ComfortTropical ClimateClimate-resilient planninOutdoor thermal comfortPolynomial regressionThermal stress classificationTropical climateTypical Meteorological YearUniversal Thermal Climate Index (UTCI)

Identifiers

PMID42778677
PMCPMC13601135

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.