Evidence map›Paper›PMID 42776445›Full record

ArticleJapanese journal of radiology2026

Technical feasibility of AI-based longitudinal multi-organ volumetry on low-dose PET/CT over 13 years.

Rika Kobayashi, Tetsuro Sekine, Shogo Imai, Koji Sohara, Takahiro Ando, Aruki Tanaka, Nahiro Yan, Hiromitsu Hayashi, Shin-Ichiro Kumita

Abstract read
PubMed Publisher
In one paragraph

Article in Japanese journal of radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Rika KobayashiDepartment of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan.
Tetsuro SekineDepartment of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan. tetsuro.sekine@gmail.com.ORCID http://orcid.org/0000-0003-1547-6696
Shogo ImaiDepartment of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan.
Koji SoharaDepartment of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan.
Takahiro AndoDepartment of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan.
Aruki TanakaDepartment of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan.
Nahiro YanDepartment of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan.
Hiromitsu HayashiDepartment of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan.
Shin-Ichiro KumitaDepartment of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to (i) compare TotalSegmentator Fast and Normal inference modes on low-dose PET/CT, (ii) evaluate whether CT denoising improves segmentation longitudinal consistency, and (iii) examine whether the selected pipeline can capture long-term within-participant volumetric trends over approximately 13 years. MATERIALS AND

methodsThis retrospective study drew from a PET/CT screening registry of 15,597 examinees. In Phase 1, 10 participants (137 scans) were selected for pipeline optimization: Fast versus Normal modes and five denoising methods were compared using detrended within-participant CV. In Phase 2, 30 participants aged ≥60 years (337 scans) were analyzed. Volumetric changes in six structures were modeled using a linear mixed-effects model with false discovery rate correction.

resultsFast mode demonstrated similar detrended longitudinal variability to Normal mode across the six analyzed structures (detrended CV range: 2.26-9.32%), with approximately 10-fold faster processing. No tested denoising method meaningfully improved the selected serial-variability metrics over raw CT. In the primary random-intercept model, all six structures showed significant population-average volumetric trends (all p < 0.001, FDR q < 0.001): autochthon (paraspinal) muscles (- 0.72%/year), iliopsoas (- 0.74%/year), liver (- 0.55%/year), kidneys (- 0.49%/year), pancreas (- 0.97%/year), and aorta (+ 0.94%/year). In the random-slope sensitivity analysis, all six structures-including the iliopsoas and aorta-remained statistically significant (all RS p < 0.01) when individual trajectory slopes were accommodated.

conclusionFast mode on raw low-dose PET/CT provided the most favorable speed-stability trade-off for TotalSegmentator-based multi-organ volumetry. Long-term within-participant volumetric trends were detectable over a 13-year follow-up, supporting technical feasibility but not yet establishing biological attribution or clinical utility.

Indexed as

Body compositionCT denoisingLongitudinal analysisLow-dose PET/CTOrgan volumetryTotalSegmentator

Identifiers

PMID42776445

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.