Evidence map›Paper›PMID 42774819›Full record

ArticleAesthetic surgery journal. Open forum2026

Reliability of a Portable Nonfixed Stereophotogrammetry System for Facial Imaging.

Marcelo Germani, Ana C N Carnevali, Pietra Roschel de Borba, Gabriela Giro, Victor R M Munoz-Lora

Abstract read
In one paragraph

Article in Aesthetic surgery journal. Open forum, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Stereophotogrammetry (3D-SQ) provides a precise alternative for the assessment of facial aesthetic procedures. Nevertheless, its accuracy could be influenced by the operator when a nonfixed device is used. The objective of the present observational study was to evaluate the reliability of a portable nonfixed 3D-SQ device. Three operators took two 3-dimensional (3D) image captures of 3 distinct volunteers using a portable nonfixed 3D-SQ device. The acquisition of images was performed at 2 different time points (F1 and F2) with a 60 min interval between each capture for each volunteer. No external lights or tripod were utilized, as recommended by the manufacturer. The photographs were processed through specialized software to generate 3D models, and a specific region of the face was analyzed to assess the reliability of the method. Interclass correlation coefficients (ICCs) of the area, perimeter, and volume of the selected region were calculated. The results demonstrated a high intraoperator consistency at all 3 obtained values (volume ICCs = 0.829; area ICCs = 0.828; perimeter ICCs = 0.673). However, a low reliability in all values across different operators was found (ICCs < 0.5). These results suggest that variations in the captures may differ among different operators. These results may be attributed to factors such as the operator height, differences in reference points, or equipment stability. The study concluded that the reliability in facial stereophotogrammetry using a nonfixed device can be influenced by the operator, exhibiting high intraoperator reliability but significant variations between different operators.

Identifiers

PMID42774819
PMCPMC13594673

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.