Evidence map›Paper›PMID 42774782›Full record

ArticlePhotoacoustics2026

A cross-shaped combined ultrasound array patch for continuous bladder volume monitoring.

Ziqi Li, Cong Pu, Ting Zhang, Chang Peng

Abstract read
In one paragraph

Article in Photoacoustics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ziqi LiSchool of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai, 201210, China.
Cong PuSchool of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai, 201210, China.
Ting ZhangDepartment of Integrative Medicine, Huashan Hospital, Fudan University, Shanghai, China.
Chang PengSchool of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai, 201210, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous monitoring of bladder volume is important for the assessment and management of lower urinary tract dysfunction. The study aims to develop a wearable non-invasive ultrasound patch for continuous bladder volume monitoring, addressing operator dependence, limited field of view (FOV), and manual probe rotation required in conventional handheld ultrasound. A cross-shaped combined ultrasound array patch (CCUA-Patch) was proposed using three 64-element linear arrays, including two vertically aligned arrays for extended sagittal imaging and one horizontal array for transverse imaging. Time-division scanning enabled multi-plane acquisition, and a feature-based stitching algorithm reconstructed a complete sagittal image. Bladder contours were automatically extracted, and volume was estimated using the prolate ellipsoid method. A 2 mm self-adhesive hydrogel layer was used to ensure stable acoustic coupling for hands-free continuous monitoring. The fabricated transducers exhibited a center frequency of 2.60 ± 0.02 MHz and a -6 dB bandwidth of 86.67 ± 2.73%. In phantom experiments, the estimated bladder volume was 126.14 mL versus a calibrated volume of 137 mL, with only 0.89 mL difference from a commercial ultrasound probe. In a pilot study of 10 healthy volunteers, the CCUA-Patch showed good agreement with the commercial device, with a mean Bland-Altman bias of 17.48 mL and most measurements falling within the 95% limits of agreement. The proposed CCUA-Patch expands the effective sagittal FOV, eliminates manual probe reorientation, and provides a practical solution for automated monitoring of the bladder volume. However, the present device used a benchtop Vantage 256 platform and only ten healthy volunteers; it therefore demonstrates the wearability and feasibility of the patch structure, not a fully wearable clinical system. Larger studies in target patient populations and integration with miniaturized, low-power readout electronics are required before clinical or home use.

Indexed as

Bladder volume monitoring Wearable ultrasound patch Cross-shaped ultrasound array Field-of-view expansion Continuous monitoring Self-adhesive hydrogel

Identifiers

PMID42774782
PMCPMC13594705

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.