Evidence map›Paper›PMID 42771331›Full record

ArticleOphthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)2026

Repeatability and Reproducibility of the Dry Eye Analyzer in Participants With and Without Symptoms of Dry Eye.

Reut Ifrah, Efrat Netanya

Abstract read
PubMed Publisher
In one paragraph

Article in Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Reut IfrahDepartment of Optometry and Vision Science, Jerusalem Multidisciplinary College, Jerusalem, Israel. reutif@edu.jmc.ac.il.
Efrat NetanyaDepartment of Optometry and Vision Science, Jerusalem Multidisciplinary College, Jerusalem, Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeReliable evaluation and consistency between examiners and sessions are essential for dry eye diagnosis. This study examined the inter-examiner reproducibility (IER), inter-session repeatability (ISR) and within-subject variability (WSV) of the Dry Eye Analyzer (DEA) in participants with and without dry eye symptoms.

methodsParticipants with Dry Eye Questionnaire-5 (DEQ-5) scores ≥6 were classified as symptomatic. Non-invasive tear breakup time (NITBUT), Meibomian gland (MG) loss, tear meniscus height (TMH), interferometry and conjunctival redness were measured by two examiners on the same day for IER. Examiner 1 repeated measurements 1-2 weeks later for ISR. Analyses included Wilcoxon tests, Spearman correlation, weighted kappa (κw), within-subject standard deviation (Sw), repeatability limits (2.77Sw), intraclass correlation coefficients (ICCs) and Bland-Altman analysis.

resultsIER included 84 participants (mean age 23 ± 2 years, range 18-34 years; 42 symptomatic). Examiner 1/Examiner 2 values were 7.2 ± 3.2/8.9 ± 3.0 s for NITBUT, 20.4 ± 7.4/20.4 ± 7.0% for upper MG loss, 27.2 ± 14.0/26.6 ± 14.0% for lower MG loss and 0.2 ± 0.0/0.2 ± 0.1 mm for TMH. Outcomes were positively correlated without significant differences for most comparisons; NITBUT differed significantly overall and in symptomatic participants. Agreement ranged from fair to good (κw 0.30-0.63), ICCs from 0.51 to 0.99 and Sw was <3.40. Mean NITBUT bias was -1.68 s overall and -2.90 s in symptomatic participants; 93-98% of observations fell within the limits of agreement. ISR included 68 participants (mean age 23 ± 2 years, range 18-32; 36 symptomatic). Session 1/Session 2 values were 7.1 ± 3.2/6.8 ± 3.1 s for NITBUT, 20.7 ± 7.4/20.7 ± 8.1% for upper MG loss, 27.0 ± 14.6/26.9 ± 13.9% for lower MG loss and 0.2 ± 0.0/0.2 ± 0.0 mm for TMH. Outcomes were positively correlated without significant differences. Agreement ranged from fair to very good (κw 0.28-1.00), with Sw < 3.14.

conclusionsDEA reliability was parameter-dependent. MG-loss measurements showed excellent IER and low WSV, whereas NITBUT showed moderate reliability and examiner-related bias. NITBUT and TMH should be interpreted cautiously during follow-up.

Indexed as

Dry Eye AnalyzerDry eye diseaseReliabilityRepeatabilityReproducibility

Identifiers

PMID42771331

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.