ArticleBiomedical optics express2026
Optical performance of minimally invasive brain implants: a simulation and phantom study.
Article in Biomedical optics express, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Despite significant progress in non-invasive techniques to sense brain activity through highly scattering biological tissue, these modalities are inherently limited by the physical process of diffusion. We explore minimally invasive transdermal and transcranial optical implants that directly reduce light diffusion by bypassing highly scattering superficial tissues, and quantitatively evaluate their impact on detected photon energy and sensitivity profiles to provide engineering insights for the optimisation of optical interface design and placement. Simulations using an anatomical head model show increased energy detection by 1-4 orders of magnitude, with improved cerebral cortex sensitivity by up to 3 orders of magnitude for longer SDS. Optical implants for SDS of a few millimetres also enable the probing of cerebral cortex with high ∼1 mm localisation. Experiments with an anatomically correct (based on an MRI scan) but simplified resin-based phantom validate the numerical modelling and show good agreement with the simulated detected energies. Further development of these optical implants could be an option for longitudinal brain sensing and imaging measurements.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.