Evidence map›Paper›PMID 42769917›Full record

ArticleIEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division2026

On Integrating Friction Dynamics Into Cosserat Models for Tendon-Driven Continuum Manipulators.

Filipe C Pedrosa, Navid Feizi, Elaheh Arefinia, Jagadeesan Jayender, Rajni V Patel

Abstract read
In one paragraph

Article in IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Filipe C PedrosaCanadian Surgical Technologies and Advanced Robotics (CSTAR), University Hospital, London, ON N6A 5A5, Canada; Department of Electrical and Computer Engineering, Western University, London, ON N6A 5A5, Canada.ORCID 0000-0001-8509-8809
Navid FeiziDepartment of Radiology at Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115 USA.ORCID 0000-0002-8656-7221
Elaheh ArefiniaCanadian Surgical Technologies and Advanced Robotics (CSTAR), University Hospital, London, ON N6A 5A5, Canada; Department of Electrical and Computer Engineering, Western University, London, ON N6A 5A5, Canada.ORCID 0000-0003-1016-4845
Jagadeesan JayenderDepartment of Radiology at Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115 USA.ORCID 0000-0002-3308-3012
Rajni V PatelCanadian Surgical Technologies and Advanced Robotics (CSTAR), University Hospital, London, ON N6A 5A5, Canada; Department of Electrical and Computer Engineering, Western University, London, ON N6A 5A5, Canada.ORCID 0000-0003-3431-4617

Funding

Robot-Assisted 3D ICE Catheter for Cardiac AblationR01EB028278 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI JAGADEESAN, JAYENDER · 2020 to 2024
$2.0M
Image-registered, Hand-held, Concentric Tube Robot for Percutaneous Treatment of CalculiR01DK119269 · NIDDK · BRIGHAM AND WOMEN'S HOSPITAL · PI JAGADEESAN, JAYENDER · 2019 to 2023
$1.8M
NIBIB NIH HHS R01 EB028278NIDDK NIH HHS R01 DK119269
6 · The paper itself

Abstract

This article presents a dynamic modeling framework for tendon-driven continuum manipulators, with a focus on cardiac catheters. Tendon compliance and tendon-sheath friction produce nonuniform tensions and motion-history-dependent dynamics (hysteresis), which, if neglected, degrade model fidelity and control. We develop a Cosserat-based formulation that integrates tendon compliance and a dynamic LuGre friction law into the governing nonlinear PDEs. This allows geometrically exact spatiotemporal computation of tendon-tension transmission without assuming initial friction states. Experiments on two clinical catheters demonstrate that incorporating friction dynamics reduces distal-tip error from 1.62±1.01 mm (frictionless) to 0.99±0.65 mm (≈39% improvement), and achieves 2.31±0.91 mm mean absolute error for out-of-plane spatial actuation of a four-tendon ICE catheter. Comparative analysis against a Coulomb-based capstan model highlights the significance of dynamic friction, which produces rate-dependent tension transmission and more accurate modeling of hysteresis effects.

Indexed as

Cardiac ablation cathetersfriction hysteresisLuGre frictiontendon-driven continuum robotstension transmission characteristics

Identifiers

PMID42769917
PMCPMC13591453

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.