ArticleCureus2026
Management of Grade III Femoral Notching During Robotic-Assisted Total Knee Arthroplasty Using a Proximal Tibial Autograft and Countersunk Screw Fixation: A Case Report.
Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Femoral notching is an iatrogenic violation of the anterior cortex of the distal femur that occurs during femoral component preparation in total knee arthroplasty (TKA). This cortical breach has been implicated as a risk factor for a future periprosthetic supracondylar fracture, particularly when the defect is deep and compromises structural integrity. Robotic systems may reduce the incidence but do not eliminate this error. We report a case of intraoperative management of a grade III femoral notching during robotic-assisted primary TKA in a 56-year-old female with Kellgren-Lawrence grade IV bilateral knee osteoarthritis and severe varus deformity, with a baseline Knee Society Score (KSS) knee score of 31 and functional score of 20. The defect was reconstructed using an autograft harvested from the proximal tibial cut, which was fashioned to fit the defect and secured with two 3.5 mm countersunk cortical screws. Following reconstruction, standard cruciate-retaining primary femoral and tibial components were implanted. The patient followed a strict non-weight-bearing regimen for four weeks, followed by protected weight-bearing for a further four weeks. At 12 months postoperatively, the patient had a range of motion of 0°-0°-120°(extension-neutral-flexion) with a KSS knee score of 99 and a functional score of 90. The radiographs showed cortical and trabecular continuity at the anterior cortex, indicating autograft incorporation and remodeling. Even though robotic and navigation systems promise precision, they are never without errors, and the need for human skill and expertise should never be overlooked. This report describes the feasibility of reconstruction of a grade III femoral notch using a structural autograft from the proximal tibial resection, avoiding conversion to a stemmed femoral component, use of allograft, or metal augments, with short-term clinical and radiographic follow-up.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials