Evidence map›Paper›PMID 42768117›Full record

ArticleSurgical endoscopy2026

Automated intracorporeal tool exchange with the Symphera multi-tool prototype: a crossover evaluation of efficiency and surgeon workload in a porcine laparoscopic model.

Fabian Haak, Conrad Heid, Brett Colton Parker, Antonello Forgione, Jacques Marescaux

Abstract read
In one paragraph

Article in Surgical endoscopy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Fabian HaakDivision of Hepatobiliary Surgery and Visceral Surgery, Department of Visceral, Transplant, Thoracic and Vascular Surgery, University Hospital Leipzig, Liebigstraße 24, 04103, Leipzig, Germany. Fabian.haak@medizin.uni-leipzig.de.ORCID http://orcid.org/0000-0002-0279-1745
Conrad HeidSymphera GmbH, Munich, Germany.
Brett Colton ParkerDivision of Minimally Invasive Surgery, Department of Surgery, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Antonello ForgioneIRCAD (Institut de Recherche Contre Les Cancers de L´Appareil Digestif), Louis Pasteur University, Strasbourg, France.
Jacques MarescauxIRCAD (Institut de Recherche Contre Les Cancers de L´Appareil Digestif), Louis Pasteur University, Strasbourg, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundConventional laparoscopic instrument exchange requires repeated trocar withdrawal, redirecting surgeon gaze and disrupting operative flow. The Symphera system enables intracorporeal tool-tip switching, but its impact on procedural efficiency, visual attention, and workload has not been evaluated in a controlled setting.

methodsTwo surgical fellows performed three standardised laparoscopic tasks (cholecystectomy, controlled hepatic bleeding, dissection-coagulation relay) under Symphera and conventional conditions in a live porcine crossover model. Primary outcomes were total task time and tool change time; secondary outcomes included gaze behaviour (eyes-on proportion, disruption events), subjective workload (SURG-TLX), device usability, and heart rate.

resultsMean total task time was 27.3 ± 10.9 vs. 33.9 ± 13.2 min (-19.6%; HL estimate -6.7 min, 95% CI -12.4 to -1.5; p = 0.10). Tool change time was reduced by 61.5% (3.6 ± 2.3 vs. 9.4 ± 6.6 min; HL estimate -5.2 min, 95% CI -9.7 to -3.4; p = 0.10). Intracorporeal exchanges were completed in a mean of 4.3 ± 4.4 s (75% within 5 s) versus 25.3 ± 23.4 s for extracorporeal exchanges. Eyes-on proportion was higher with Symphera (86.0 ± 10.9% vs. 78.1 ± 9.8%; HL estimate + 7.7 pp, 95% CI + 0.9 to + 14.8; p = 0.031), with instrument exchange as a gaze disruption cause markedly reduced. SURG-TLX scores were 44.8% lower with Symphera (40.2 ± 15.8 vs. 72.9 ± 19.8), with reductions across all six dimensions.

conclusionSymphera demonstrated favourable trends in procedural efficiency, gaze behaviour, and subjective workload versus conventional instrument exchange. The convergence of behavioural, subjective, and efficiency data supports the hypothesis that intracorporeal exchange preserves visual attention and may reduce perceived workload. Larger, adequately powered studies are warranted.

Indexed as

LaparoscopesLaparoscopyWorkloadAnimalsCross-Over StudiesEquipment DesignModels, AnimalOperative TimeSwineInstrument exchangeIntracorporeal tool switchingLaparoscopic instrumentsMinimally invasive surgerySurgical workflowWorkload

Identifiers

PMID42768117
PMCPMC13633380

What OpenQuestion holds

Textmetadata
Read underepoch 390