ArticleMikrochimica acta2026
Development of a graphene oxide-based PEGylated fluorescent aptasensor with ultrahigh-sensitivity and anti-fouling properties for the detection of serum carcinoembryonic antigen levels.
Article in Mikrochimica acta, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
The specificity and sensitivity of aptamer-based serum biomarker assays can be compromised by nonspecific adsorption of proteins. In this study, we used the carcinoembryonic antigen (CEA) aptamer as a model to develop a fluorescent aptasensor capable of specifically and sensitively detecting serum biomarkers. This aptasensor employs the good antifouling capability of polyethylene glycol 2000 (P2K) to enhance specificity and the good fluorescence resonance energy transfer capability of graphene oxide (GO) to improve sensitivity. The aptasensor was applied to determine pure CEA protein and CEA in clinical serum and demonstrated that the P2K-modified fluorescent aptasensor exhibited significantly superior performance in CEA detection compared with the unmodified aptasensor, including accuracy, precision, linear range, antifouling properties, and selectivity. In the detection of CEA levels in clinical serum samples, the P2K-modified fluorescent aptasensor exhibited a lower limit of detection (LOD) (1.31 vs. 1.90 ng/mL), a wider linear range (1-256 vs. 1-64 ng/mL), better recovery (92.4%-103.6% vs. 73.3%-124.1%), and a smaller relative standard deviation (RSD) (0.7%-2.5% vs. 2.0%-6.4%). The aptasensor is capable of determining CEA levels within 90 min using only 1 µL of serum, with advantages of requiring no prefabrication of sensors, measuring fluorescence intensity in a conventional microplate reader, operating experimentally at room temperature, and high-throughput detection. Conclusively, this study successfully developed a GO-based P2K-modified fluorescent aptasensor capable of specifically, sensitively, and conveniently detecting CEA levels in clinical serum samples and with potential for clinical application.
Indexed as
Identifiers
42766210What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.