Evidence map›Paper›PMID 42765028›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2026

MedFoundationHub: A Lightweight and Secure Toolkit for Deploying Medical Vision Language Foundation Models.

Xiao Li, Yanfan Zhu, Ruining Deng, Wei-Qi Wei, Yu Wang, Shilin Zhao, Yaohong Wang, Haichun Yang, Yuankai Huo

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xiao LiVanderbilt University, Nashville TN 37235, USA.
Yanfan ZhuVanderbilt University, Nashville TN 37235, USA.
Ruining DengWeill Cornell Medicine, New York, NY 10021, USA.
Wei-Qi WeiVanderbilt University Medical Center, Nashville TN 37232, USA.
Yu WangVanderbilt University Medical Center, Nashville TN 37232, USA.
Shilin ZhaoVanderbilt University Medical Center, Nashville TN 37232, USA.
Yaohong WangUT MD Anderson Cancer Center,TX 77030, USA.
Haichun YangVanderbilt University Medical Center, Nashville TN 37232, USA.
Yuankai HuoVanderbilt University, Nashville TN 37235, USA.

Funding

Complementary ex vivo multimodal optical imaging and in vivo Raman spectroscopy to understand tissue dynamicsR01EB033385 · NIBIB · VANDERBILT UNIVERSITY · PI MAHADEVAN-JANSEN, ANITA, REESE, JOHN JEFFREY · 2022 to 2025
$2.6M
AI-empowered 3D Computer Vision and Image-Omics Integration for Digital Kidney HistopathologyR01DK135597 · NIDDK · VANDERBILT UNIVERSITY · PI Yuankai Huo · 2023 to 2026
$2.1M
Dual-wavelength endoscopic Raman probe for eosinophilic esophagitisR01DK132338 · NIDDK · VANDERBILT UNIVERSITY · PI MAHADEVAN-JANSEN, ANITA · 2022 to 2025
$1.7M
NIBIB NIH HHS R01 EB033385NIDDK NIH HHS R01 DK132338NIDDK NIH HHS R01 DK135597
6 · The paper itself

Abstract

Recent advances in medical vision-language models (VLMs) open up remarkable opportunities for clinical applications such as automated report generation, physician copilots, and uncertainty quantification. Despite their promise, medical VLMs raise serious security concerns. These include the risk of Protected Health Information (PHI) exposure, data leakage, and vulnerability to cyberthreats, concerns that are especially critical in hospital environments. Even when adopted for research or non-clinical purposes, healthcare organizations must exercise caution and implement safeguards. To address these challenges, we present MedFoundationHub, a graphical user interface (GUI) toolkit that: (1) enables physicians to manually select and use different models without programming expertise, (2) supports engineers in efficiently deploying medical VLMs in a plug-and-play fashion, with seamless integration of Hugging Face open-source models, and (3) ensures privacy-preserving inference through Docker-orchestrated, operating system agnostic deployment. MedFoundationHub requires only an offline local workstation equipped with a single NVIDIA A6000 GPU, making it both secure and accessible within the typical resources of academic research labs. To evaluate current capabilities, we engaged board-certified pathologists to deploy and assess five state-of-the-art VLMs (Google-MedGemma3-4B, Qwen2-VL-7B-Instruct, Qwen2.5-VL-7B-Instruct, and LLaVA-1.5-7B/13B). Expert evaluation covered colon cases and renal cases, yielding 1,015 clinician-model scoring events. These assessments revealed recurring limitations, including off-target answers, vague reasoning, and inconsistent pathology terminology.

Identifiers

PMID42765028
PMCPMC13590015

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.