Validation of Automated Fixed Force Applanation Tonometry.

Joanne C Wen, Rohan Vora, Hongyi Jiang, Stuart McKinnon, Kelly W Muir, Stacy L Tantum

Abstract read
In one paragraph

Article in Ophthalmology science, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Joanne C WenDuke Eye Center, Duke University, Durham, North Carolina.
Rohan VoraDepartment of Electrical and Computer Engineering, Duke University, Durham, North Carolina.
Hongyi JiangDepartment of Electrical and Computer Engineering, Duke University, Durham, North Carolina.
Stuart McKinnonDuke Eye Center, Duke University, Durham, North Carolina.
Kelly W MuirDuke Eye Center, Duke University, Durham, North Carolina.
Stacy L TantumDepartment of Electrical and Computer Engineering, Duke University, Durham, North Carolina.

Funding

Measuring Ocular Pulse Amplitude with Fixed Force Applanation on Normotensive and Hypertensive EyesR21EY036170 · NEI · DUKE UNIVERSITY · PI Joanne Wen · 2025 to 2026
$440k
NEI NIH HHS R21 EY036170
6 · The paper itself

Abstract

Purpose: To validate fixed force applanation tonometry against traditional Goldmann applanation tonometry (GAT) and compare interuser reproducibility. Design: Prospective cross-sectional pilot study. Subjects: Patients presenting for their routine eye care at an academic glaucoma practice. Methods: A prototype adaptor containing a camera was attached to the Goldmann tonometer of a standard slitlamp microscope set to a fixed force in conjunction with a custom tonometer tip. Recorded applanation mires were converted to an intraocular pressure (IOP) using the Imbert-Fick formula. Standard GAT was also performed. Clinical GAT, research GAT, and prototype IOP measurements among different users were also completed. Main Outcome Measures: Goldmann applanation tonometry and prototype IOPs were compared in a pilot validation study, and interuser reproducibility was assessed using the 2 devices. Results: In the validation study, 100 eyes from 50 subjects were included. The mean difference between the prototype and standard GAT measurements was +1.0 mmHg, with 95% limits of agreement (LoA) of -3.4 to 5.5 mmHg. The mean absolute difference (± standard deviation) between the prototype IOP and the standard GAT measurement was 1.9 ± 1.5 mmHg. In the reproducibility study, 42 eyes from 21 subjects were included. The mean difference between the research technician prototype IOP and the ophthalmologist prototype IOP measurements was 0.01 mmHg with LoA of -2.5 to 2.4 mmHg. The mean absolute difference between users was significantly lower when using the prototype compared with standard GAT (0.9 ± 1.2 mmHg vs. 1.6 ± 1.1 mmHg, Conclusions: Preliminary measurements using a fixed force applanation tonometry method demonstrated comparable results with standard GAT with improved interuser reproducibility. Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.

Indexed as

Applanation tonometryAutomatedIntraocular pressureTonometerTonometry