Evidence map›Paper›PMID 42763403›Full record

ArticleBMC musculoskeletal disorders2026

Optimized anterior anatomical fusion plate for ankle arthrodesis: biomechanical and clinical outcomes.

Yi Liu, Yaokuan Ruan, Zhende Jiang, Shichen Hu, Aoran Zhang, Nan Mei, Fei Chang

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yi LiuDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Yaokuan RuanDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Zhende JiangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Shichen HuDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Aoran ZhangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Nan MeiDepartment of Orthopedic Surgery, Nara Medical University, Nara, Japan.
Fei ChangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China. changfei@jlu.edu.cn.

Funding

Department of Finance of Jilin Province 2024WSZX-B10National Key Research and Development Program of China 2022YFE0107700the Scientific Research Project of the Jilin Provincial Department of Education JJKH20262164BS
6 · The paper itself

Abstract

backgroundAnkle osteoarthritis (OA) is a common degenerative joint disorder that often necessitates ankle arthrodesis. Conventional fusion methods may offer limited fixation stability and require extensive soft-tissue exposure. The goal of this study was to evaluate the biomechanical properties of a geometrically optimized anterior anatomical fusion plate (AAFP) for ankle arthrodesis, which has been designed to enhance mechanical performance and minimize surgical trauma.

methodsThis study developed a finite element model of the ankle based on CT scans of a healthy male volunteer. Various fusion models were created, incorporating the optimized AAFP with or without transarticular screw, anterolateral fusion plate (ALFP) with or without transarticular screw, and configurations using three or two screws. The biomechanical performance of these systems was assessed by analyzing peak displacement of the fusion surface and peak von Mises stress of implants and bone-implant models under seven common ankle postures. Additionally, the preliminary feasibility of the optimized AAFP was assessed by analyzing the American Orthopaedic Foot & Ankle Society (AOFAS) scores and X-ray images.

resultsThe optimized AAFP with transarticular screw fixation exhibited great stability, with peak displacement of 0.14 mm in neutral position, 0.19 mm in dorsiflexion, 0.07 mm in plantar flexion, 0.09 mm in internal rotation, 0.07 mm in external rotation, 0.10 mm in inversion, and 0.12 mm in eversion. The peak stress of the fusion method was relatively low, with 132.91 MPa in neutral position, 145.83 MPa in dorsiflexion, 97.15 MPa in plantar flexion, 84.27 MPa in internal rotation, 74.70 MPa in external rotation, 98.07 MPa in inversion, and 88.00 MPa in eversion. The transarticular screw enhanced biomechanical stability of the optimized AAFP in ankle fusion by reducing stress and displacement. Clinically, the optimized AAFP showed satisfactory short-term outcomes, with improvements in the AOFAS scores (from 53 to 83, 57 to 82, 51 to 84 and 57 to 83) and imaging results.

conclusionsThese findings suggest that the geometrically optimized AAFP combines a smaller incision with favorable biomechanical performance and warrants further clinical evaluation as a potential option for ankle fusion.

Indexed as

Ankle JointArthrodesisBone PlatesOsteoarthritisAdultBiomechanical PhenomenaBone ScrewsFinite Element AnalysisHumansMaleTomography, X-Ray ComputedTreatment OutcomeBiomechanicsFinite Element AnalysisFoot and AnkleFusion and Arthrodesis

Identifiers

PMID42763403
PMCPMC13589351

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked