ArticleMagma (New York, N.Y.)2026
Design of a nonlinear double-breast single-axis gradient coil with controlled anterior-posterior gradient variation for diffusion-weighted imaging.
Article in Magma (New York, N.Y.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
introductionHigh-performance whole-body gradient systems show promise for breast diffusion-weighted imaging, but their performance is constrained by physiological limits. Although local nonlinear gradient coils can provide stronger gradients while remaining within these limits, they often exhibit a substantial reduction in the gradient amplitude of the z-component of the magnetic field near the chest wall.
methodsWe introduced an optimization framework incorporating a constraint on the anterior-posterior variation in the encoding gradient amplitude. A figure of merit combining coil efficiency and minimum wire width was defined to assess performance. A prototype was constructed to validate the design methodology.
resultsThe optimized coil achieved a 2.35-fold efficiency increase over standard linear coils. Compared to previous nonlinear designs, the new constraint reduced spatial variation by 35.7% and improved minimum efficiency near the chest wall by 2.6-fold. Experimental field maps matched simulations with errors under 8%. DISCUSSION: The proposed method effectively mitigates the trade-off between gradient strength and spatial uniformity along anterior-posterior direction. By enhancing performance in the posterior breast region, the design addresses a critical limitation of previous local coils.
conclusionThis framework enables the development of high-performance, robust local gradient coils, facilitating the clinical implementation of advanced DWI protocols for breast cancer screening.
Indexed as
Identifiers
42762377What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.