Evidence map›Paper›PMID 42761754›Full record

ArticleResuscitation plus2026

Accuracy of ventilation feedback devices compared with a reference standard during asynchronous ventilation with continuous chest compressions in a simulated cardiac arrest: a prospective non-randomized cross-over study.

Christophe Duchatelet, Kristof Segher, Thomas Tackaert, Maxim Vanwulpen, Bert Ingels, Dimitri Muylaert, Said Hachimi-Idrissi

Abstract read
In one paragraph

Article in Resuscitation plus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Christophe DuchateletFaculty of Medicine and Health Sciences, Ghent University, Sint-Pietersnieuwstraat 25, Ghent, Belgium.
Kristof SegherDepartment of Emergency Medicine, AZ Alma, Ringlaan 15, 9900 Eeklo, Belgium.
Thomas TackaertFaculty of Medicine and Health Sciences, Ghent University, Sint-Pietersnieuwstraat 25, Ghent, Belgium.
Maxim VanwulpenFaculty of Medicine and Health Sciences, Ghent University, Sint-Pietersnieuwstraat 25, Ghent, Belgium.
Bert IngelsDepartment of Emergency Medicine, AZ Alma, Ringlaan 15, 9900 Eeklo, Belgium.
Dimitri MuylaertDepartment of Emergency Medicine, AZ Alma, Ringlaan 15, 9900 Eeklo, Belgium.
Said Hachimi-IdrissiFaculty of Medicine and Health Sciences, Ghent University, Sint-Pietersnieuwstraat 25, Ghent, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimThis study aimed to evaluate the accuracy of two commercially available ventilation feedback devices (VFD) in measuring ventilation rate and tidal volume during simulated cardiopulmonary resuscitation (CPR) with continuous chest compressions and asynchronous ventilations in the presence of reversed airflow. Methods: Prospective, simulation-based, non-randomized cross-over study. Twenty emergency department nurse practitioners performed manual ventilation on an intubated high-fidelity manikin during two 1-minute trials (one per device), targeting 10 breaths/min during continuous chest compressions (100-120/min). Ventilation parameters displayed by EOLifeX® and AccuVent® were compared with measurements from a high-fidelity pneumotachograph (HFRP). Data is presented as mean (standard deviation, min-max range). CI = confidence interval. Results: Conclusion: During simulated CPR with continuous compressions and asynchronous ventilations, VFDs demonstrated clinically relevant inaccuracies. Validation under realistic resuscitation conditions are needed.

Indexed as

Cardiac arrestOHCAResuscitationVentilationVentilation feedback devices

Identifiers

PMID42761754
PMCPMC13587069

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.