Evidence map›Paper›PMID 42757322›Full record

ArticleGMS hygiene and infection control2026

Using a basic life support stress-test to assess the influence of ethanol-based hand rubs nitril gloves and of physically demanding clinical tasks on personal protective equipment fit (GLOVDIS-1) - a pilot Manikin study.

Tobias P Taubner, Michael Bentele, Florian Salm, Dario Zocholl, Benjamin Taubner, Stefan Bushuven, Nico T Mutters

Abstract read
In one paragraph

Article in GMS hygiene and infection control, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tobias P TaubnerUniversity of Bonn, University Hospital Bonn, Institute of Hygiene and Public Health, Bonn, Germany.
Michael BenteleTraining Center for Emergency Medicine (NOTIS e.V.), Pfronten, Germany.
Florian SalmPrevent Infect Akademie, Freiburg, Germany.
Dario ZochollInstitute for Medical Biometry, Informatics and Epidemiology, Medical Faculty, University of Bonn, Germany.
Benjamin TaubnerInstitute for Psychology, University Bern, Switzerland.
Stefan BushuvenTraining Center for Emergency Medicine (NOTIS e.V.), Pfronten, Germany.
Nico T MuttersUniversity of Bonn, University Hospital Bonn, Institute of Hygiene and Public Health, Bonn, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: Hand hygiene and personal protective equipment (PPE) are essential components for infection control. However, existing data are inconclusive regarding the impact of ethanol-based hand rubs on glove integrity, and evidence is limited on whether individual PPE components maintain adequate fit and usability during physically demanding clinical tasks. This pilot study aimed to evaluate the feasibility of a simulation-based protocol, designed to investigate hygiene- and PPE-related benefits and limitations under realistic emergency conditions. Methods: In a prospective observational study, 60 health care workers (HCW) pairwise performed two cycles of cardiopulmonary resuscitation (CPR) according to Basic Life Support standards while wearing full personal protective equipment. Participants were double-gloved; outer gloves were disinfected with an ethanol-based hand rub (EBHR), while the inner gloves remained native. Glove integrity was assessed according to DIN EN 455-1, and subjective PPE fit was rated before and after CPR. Feasibility, glove leakage, and changes in PPE fit were analyzed descriptively and exploratorily. Results: The study protocol proved feasible, with no dropouts and successful integrity testing of 478 out of 480 gloves. Glove leakage occurred in 3.8% of gloves, with no significant difference between disinfected and native gloves. Subjective PPE fit remained unchanged for gloves, respirators, and eye protective devices, whereas gown fit deteriorated significantly after CPR. Conclusion: This pilot study demonstrates the feasibility of a standardized simulation-based Basic Life Support stress test to investigate the influence of glove disinfection with two different EBHRs on PPE performance under simulated emergency conditions. Ethanol-based glove disinfection did not increase glove leakage, whereas gown fit deteriorated during CPR. Larger, adequately powered studies may base on these results to further evaluate PPE performance and inform evidence-based infection prevention strategies in emergency care.

Identifiers

PMID42757322
PMCPMC13585032

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.