ArticleFrontiers in oncology2026
Beyond the snapshot: continuous optical surface monitoring reveals non-linear temporal dynamics and postural stability window in free-breathing breast radiotherapy.
Article in Frontiers in oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: This study aimed to evaluate the clinical consistency between AlignRT surface monitoring and fan-beam computed tomography (FBCT)-based single-timepoint volumetric verification in free breathing (FB) breast radiotherapy, and to quantitatively characterize the nonlinear temporal dynamics of intrafractional motion. Materials and methods: A retrospective analysis was conducted on 485 FB volumetric modulated arc therapy (VMAT) fractions from 38 patients treated following breast conserving surgery. Intrafractional motion was monitored concurrently using FBCT (endpoint positional snapshots) and AlignRT (continuous six degree of freedom tracking). Raw surface signals were decomposed into baseline drift and respiratory motion components using a 0.05 Hz zero phase low pass filter. Linear mixed effects models (LMMs) and segmented regression analyses were employed to evaluate clinical predictors and characterize temporal stability patterns. Results: Both AlignRT and FBCT demonstrated excellent agreement along the lateral axis (median difference, 0.021 mm). In contrast, the vertical axis exhibited opposing directional shifts, in which FBCT indicated a slight anterior displacement (0.06 mm), whereas AlignRT detected a posterior drift (-0.17 mm), likely reflecting differences between internal bony expansion and external soft tissue deformation. LMM analysis revealed that higher respiratory frequency was significantly associated with reduced motion amplitudes. Segmented regression identified a multiphasic temporal trajectory, including an observed "stability window" between 100.7 s and 138.8 s, after which postural degradation significantly increased. Conclusions: AlignRT provides an indispensable continuous-tracking supplement to single-timepoint FBCT. A shallow, rapid breathing pattern and treatment delivery within the ~100-140s stability window may help optimize posture maintenance. Continuous surface monitoring may therefore play a critical role in maintaining dosimetric accuracy during extended treatment delivery.