ArticleOrthopaedic surgery2026
Inter-Session Repeatability of a Smartphone-Based Markerless System to Measure Segment Length and Lower-Limb Kinematics in Patients With End-Stage Knee Osteoarthritis.
Article in Orthopaedic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
backgroundWhile kinematic analysis is crucial to characterize multi-planar functional deficits in end-stage knee osteoarthritis (OA), traditional laboratories impose severe physical burdens on patients. In-field markerless systems like OpenCap offer an accessible alternative, yet their repeatability in this population remains underexplored. The objective of this study was to assess the inter-session repeatability of OpenCap for quantifying segment lengths and lower-limb kinematics during gait and sit-to-stand tasks in end-stage knee osteoarthritis (OA) patients.
methodsTwenty-three patients with end-stage knee OA scheduled for total knee arthroplasty performed gait and sit-to-stand tasks while wearing street clothes across two visits. Segment lengths obtained from static calibration were compared between sessions, while waveform repeatability of lower-limb joint angles was assessed using root mean square deviation (RMSD) and intraclass correlation coefficient (ICC). Additionally, the standard error of measurement (SEM) and minimal detectable change (MDC) were calculated for discrete kinematic parameters.
resultsThe segment lengths exhibited moderate to excellent repeatability between sessions (mean ICC: 0.79). Measurement bias was generally minimal (< 0.5 cm, except for the upper arm), with the overall 95% limits of agreement ranging from -4.51 to 3.98 cm. For gait, the average RMSD and ICC values were 4.0° (SD: 0.9) and 0.82 (SD: 0.07), respectively, whereas for the sit-to-stand task, these values were 5.2° (SD: 1.1) and 0.69 (SD: 0.08), respectively. The average SEM and MDC values for gait were 2.9° and 8.0°, and for sit-to-stand, 3.0° and 8.4°, respectively.
conclusionsOpenCap demonstrates moderate to good inter-session repeatability for static anatomical measurements and gait kinematics in patients with end-stage knee OA, showing promise as a low-burden clinical assessment tool. However, the higher variability observed during the sit-to-stand task necessitates cautious, task-specific interpretation, underscoring the need for further improvements before expanding its use across broader functional assessments.