Evidence map›Paper›PMID 42751203›Full record

ArticleArthroplasty today2026

Mid-Term Analysis of Serum Metal Ion Levels Comparison Between Monoblock and Modular Dual Mobility Components: A Source for Concern?

Henry Somerby, David Mayman, Allina Nocon, Eoin Devoy, Ittai Shichman, Thomas Sculco, Peter Sculco

Abstract read
In one paragraph

Article in Arthroplasty today, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Henry SomerbyStavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
David MaymanStavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
Allina NoconStavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
Eoin DevoyStavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
Ittai ShichmanStavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
Thomas SculcoStavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.
Peter SculcoStavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Dislocation is one of the most prevalent complications in total hip arthroplasty. A leading recommendation to prevent dislocation is dual mobility (DM) constructs. The monoblock DM design features a one-piece shell with a mobile polyethylene liner, whereas the newer modular DM design holds a fixed liner within a standard cup. Despite several advantages, an additional bearing surface is concerning for fretting and metal ion release. Previously, we found the frequency of serum metal ions was greater in modular than monoblock at the 1-year time point. Elevated metal ion values may be associated with adverse local tissue reactions; therefore, we continued monitoring at 5 years. Methods: Three high-yield surgeons who used DM constructs included metal ion tests in their clinical practice. Patients with a monoblock/modular construct implanted between 2015 and 2019 were asked to complete metal ion testing at 5 years. Results were interpreted based on standardized metal ion ranges. Results: We contacted 98 patients from our previous study. Three patients had died, seven were lost to follow-up, leaving 88 patients eligible for continued monitoring. Fifty-two (57%) patients returned (monoblock, N = 22; modular, N = 30). Five-year mean metal ion values were the following: cobalt (0.83 ± 0.412), chromium (0.91 ± 1.3), and titanium (5.4 ± 4.3). Monoblock had higher chromium levels than modular (1.2 vs 0.69) but there was no significant difference in mean metal ions. Conclusions: We found no metal ion level differences between monoblock/modular constructs at 5 years. Future studies are needed to determine if normal metal ion results between constructs equate to similar clinical outcomes.

Indexed as

Dual mobilityMetal ionsMetallosisTotal hip arthroplasty

Identifiers

PMID42751203
PMCPMC13579317

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.