ArticleAnalytical sciences : the international journal of the Japan Society for Analytical Chemistry2026
An automated endpoint control platform for a cyclone concentration pipette.
Article in Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
In the point-of-care, microfluidic, and biochemistry areas, the sample volume is becoming as small as µL order. In this study, we introduce a cyclone concentration pipette that integrates quantitative concentration and sample ejection functions for liquid volume conversion (mL to µL). The concentration pipette is a three-scale polypropylene (PP) tube comprising a cm-scale cyclone concentration chamber, a mm-scale channel for keeping the 10 µL liquid, and a µm-scale orifice (105 µm ± 6 µm) for ejecting liquid. The cyclone concentration system requires continuous observation to determine the endpoint (10 µL). This work introduces an automated control system designed for precise control of a 10 µL volume. The system is built on a Raspberry Pi platform with a Logitech C920 USB camera (1920 × 1080). It monitors the tube in real-time using three parallel detection methods: a convolutional neural network (CNN) for liquid state classification, a MOG2 background subtractor for droplet movement detection, and temporal pixel variance analysis across a 40-frame rolling window for flow state monitoring. When no activity is detected by any method for 30 consecutive seconds, the Raspberry Pi automatically closes a KOGANEI proportional pneumatic valve via a PWM-to-voltage converter (0-10 V). The system automatically terminated concentration without manual intervention. For the water concentration, the mean final volume was 10.6 μL with a standard deviation of 1.65 μL, corresponding to a coefficient of variation (CV) of 15.6% and a bias of + 6.0% relative to the target volume of 10 μL (n = 10). The optimized imaging conditions improved the stability of endpoint detection and volume control, resulting in a final volume of 10.4 μL (CV = 8.2%) with a bias of + 4.0% relative to the 10 μL target, demonstrating acceptable endpoint control accuracy. For the Sunset Yellow solution, a recovery of > 90% and a concentration factor of approximately 90-fold were achieved, indicating that the automated control strategy maintained high sample recovery while achieving efficient concentration.
Indexed as
Identifiers
42749896What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.