Evidence map›Paper›PMID 42748270›Full record

ArticleScience advances2026

Concurrent excitation and detection in magnetic resonance using voltage-controlled oscillators.

Zhibin Zhao, Michal Kern, Weiyi Zhang, Qing Yang, Katja Drerup, Felix Schuderer, Samuel Wazynski, Bernhard Blümich, Klaus Lips, Klaus Scheffler and 1 more

Abstract read
In one paragraph

Article in Science advances, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Zhibin ZhaoInstitute of Smart Sensors, University of Stuttgart, 70569 Stuttgart, Germany.ORCID 0009-0007-4660-0211
Michal KernInstitute of Smart Sensors, University of Stuttgart, 70569 Stuttgart, Germany.ORCID 0000-0001-9376-4568
Weiyi ZhangInstitute of Smart Sensors, University of Stuttgart, 70569 Stuttgart, Germany.ORCID 0009-0009-3011-1135
Qing YangInstitute of Smart Sensors, University of Stuttgart, 70569 Stuttgart, Germany.
Katja DrerupInstitute of Smart Sensors, University of Stuttgart, 70569 Stuttgart, Germany.
Felix SchudererInstitute of Smart Sensors, University of Stuttgart, 70569 Stuttgart, Germany.
Samuel WazynskiInstitute of Smart Sensors, University of Stuttgart, 70569 Stuttgart, Germany.ORCID 0009-0009-4377-582X
Bernhard BlümichInstitut für Technische und Makromolekulare Chemie, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0002-1152-4438
Klaus LipsBerlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Berlin, Germany.ORCID 0000-0003-4691-7239
Klaus SchefflerHigh-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, 72076 Tübingen, Germany.ORCID 0000-0001-6316-8773
Jens AndersInstitute of Smart Sensors, University of Stuttgart, 70569 Stuttgart, Germany.ORCID 0000-0002-2498-0352

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dead time following radio frequency excitation limits pulsed magnetic resonance (MR) experiments by obscuring early-time spin dynamics and short-lived signals. We demonstrate continuous concurrent excitation and detection using two oscillator-based MR detectors: a high-frequency (477 megahertz) injection-locked voltage-controlled oscillator (VCO) array enabling a scalable segmented-coil architecture and a low-frequency (17 megahertz) single-coil VCO. Both detectors are embedded in custom-designed phase-locked loops, enabling phase-coherent multipulse operation. Using a planar segmented coil driven by a chip-integrated VCO array operating at 477-megahertz proton frequency, we perform conventional Fourier transform nuclear MR, continuously monitor driven Rabi oscillations throughout the excitation pulse, and observe the immediate onset of free-induction decay, all without dedicated transmit-receive switches or receiver gating. We further demonstrate phase-coherent, phase-cycled multipulse operation, including a Hahn echo sequence realized on a second system operating at 17 megahertz. Together, these results demonstrate the general applicability and versatility of the oscillator-based detection principle across pulse sequences and operating frequencies.

Identifiers

PMID42748270
PMCPMC13580536

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.