Evidence map›Paper›PMID 42746020›Full record

ArticleEuropean heart journal. Case reports2026

Transjugular LuX-Valve Plus transcatheter tricuspid valve replacement for torrential tricuspid regurgitation in a patient with a giant right atrium and multiple prior valve interventions: a case report.

Quntai Qiu, Xinlei Wu, Daozhu Wu, Xinmin Zhang, Lianpin Wu

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Quntai QiuZhejiang-Ireland Joint Laboratory for Precision Diagnosis and Treatment of Valvular Heart Diseases, The Second Affiliated Hospital of Wenzhou Medical University, 1111 East Wenzhou Avenue, Longwan, Wenzhou 325024, China.ORCID https://orcid.org/0009-0009-4646-7777
Xinlei WuZhejiang-Ireland Joint Laboratory for Precision Diagnosis and Treatment of Valvular Heart Diseases, The Second Affiliated Hospital of Wenzhou Medical University, 1111 East Wenzhou Avenue, Longwan, Wenzhou 325024, China.ORCID https://orcid.org/0000-0001-7383-8961
Daozhu WuZhejiang-Ireland Joint Laboratory for Precision Diagnosis and Treatment of Valvular Heart Diseases, The Second Affiliated Hospital of Wenzhou Medical University, 1111 East Wenzhou Avenue, Longwan, Wenzhou 325024, China.
Xinmin ZhangZhejiang-Ireland Joint Laboratory for Precision Diagnosis and Treatment of Valvular Heart Diseases, The Second Affiliated Hospital of Wenzhou Medical University, 1111 East Wenzhou Avenue, Longwan, Wenzhou 325024, China.
Lianpin WuZhejiang-Ireland Joint Laboratory for Precision Diagnosis and Treatment of Valvular Heart Diseases, The Second Affiliated Hospital of Wenzhou Medical University, 1111 East Wenzhou Avenue, Longwan, Wenzhou 325024, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transcatheter tricuspid valve replacement (TTVR) is an option for selected patients with severe tricuspid regurgitation (TR) who are at high surgical risk, but experience remains limited in those with extreme right-heart anatomy, including a giant right atrium and a markedly enlarged elliptical tricuspid annulus. Case summary: A 62-year-old man was admitted with progressive dyspnoea and lower-extremity oedema (NYHA class IV). He had previously undergone mechanical mitral valve replacement and transcatheter aortic valve replacement. Echocardiography and computed tomography angiography (CTA) showed torrential TR, a giant right atrium (11.59 × 7.73 cm), preserved right ventricular systolic function, and a markedly elliptical annulus with a perimeter-derived diameter of 55.5 mm. Persistent TR despite satisfactory left-sided prosthetic valve function prompted transcatheter evaluation. Redo surgery was prohibitive and transcatheter edge-to-edge repair was unsuitable. The Heart Team selected LuX-Valve Plus because its leaflet graspers and septal anchor provide radial force-independent multipoint fixation. A 79.2-mm bend-point-to-annulus distance exceeded the proposed 45-70 mm range, requiring a slightly lateral jugular entry angle and complicating depth control and coaxial alignment. The mechanical mitral prosthesis limited visualization by transoesophageal echocardiography (TEE) but served as a fluoroscopic landmark; TEE and fluoroscopy enabled successful implantation. At 1 month, NYHA class improved to II, with stable prosthetic haemodynamics, no obvious transvalvular regurgitation, and trivial paravalvular leak; findings remained stable at 6-7 weeks. Discussion: This case highlights the feasibility of transjugular LuX-Valve Plus TTVR in extreme right-heart anatomy and emphasizes the importance of anatomy-driven device selection, tailored delivery and imaging strategies, and individualized postprocedural management.

Indexed as

Case reportGiant right atriumLuX-Valve PlusTranscatheter tricuspid valve replacementTricuspid regurgitation

Identifiers

PMID42746020
PMCPMC13575680

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.