Evidence map›Paper›PMID 42741076›Full record

ArticleFrontiers in cardiovascular medicine2026

Medium-term clinical and imaging outcomes of SilverFlow covered bridging stent implantation using

Xiangyang Shu, Daping Zhang, Pengfei Zhou, Zongjiang Yang, Zhaoxiong Deng, Guangning Liu

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xiangyang ShuDepartment of Vascular Surgery, People's Hospital of Qiandongnan Miao and Dong Autonomous, Prefecture, Kaili, Guizhou, China.
Daping ZhangDepartment of Vascular Surgery, People's Hospital of Qiandongnan Miao and Dong Autonomous, Prefecture, Kaili, Guizhou, China.
Pengfei ZhouDepartment of Vascular Surgery, People's Hospital of Qiandongnan Miao and Dong Autonomous, Prefecture, Kaili, Guizhou, China.
Zongjiang YangDepartment of Vascular Surgery, People's Hospital of Qiandongnan Miao and Dong Autonomous, Prefecture, Kaili, Guizhou, China.
Zhaoxiong DengDepartment of Vascular Surgery, People's Hospital of Qiandongnan Miao and Dong Autonomous, Prefecture, Kaili, Guizhou, China.
Guangning LiuDepartment of Vascular Surgery, People's Hospital of Qiandongnan Miao and Dong Autonomous, Prefecture, Kaili, Guizhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Evidence regarding the medium-term performance of SilverFlow covered bridging stents for in-situ fenestrated aortic arch repair remains limited. This study evaluated the clinical and imaging outcomes of SilverFlow covered bridging-stent implantation for the treatment of aortic arch lesions. Methods: This single-centre, single-arm retrospective cohort study included consecutive adult patients who underwent in-situ fenestrated aortic arch repair with SilverFlow covered bridging stents between January 2023 and April 2025. The primary outcome was technical success. Secondary outcomes included 30-day major adverse events, mortality, target-vessel patency, aortic remodelling, and reintervention rates. Results: Eighty-one patients received 140 SilverFlow covered bridging stents. Technical success was achieved in 70 patients (86.4%). Successful stent deployment, completion of planned fenestrations, and immediate target-vessel patency were each achieved in 98.8% of cases. No intraoperative, in-hospital, or 30-day deaths occurred. The 30-day major adverse-event rate was 25.9%. At 12 months, all 107 assessed branch vessels remained patent. At the latest imaging follow-up, per-vessel and patient-level patency rates were 98.5% and 97.5%, respectively. Significant reductions were observed in maximum aortic diameter (-4.0 mm, P = 0.020), false-lumen diameter (-6.8 mm, P < 0.001), and aneurysm-sac diameter (-8.5 mm, P = 0.010). Complete false-lumen thrombosis increased from 32.5% to 55.0% (P = 0.020). During a median follow-up of 19.0 months, four patients died and seven required aortic- or branch-related reintervention. Freedom from reintervention was 92.4% at 12 months and 90.8% at 24 months. Discussion: In this single-centre cohort, in-situ fenestrated aortic arch repair using SilverFlow covered bridging stents demonstrated high immediate reconstruction success, durable target-vessel patency among assessed vessels, and favourable imaging indicators of aortic remodelling during medium-term follow-up. These findings support the feasibility of this technique; however, comparative studies are required to determine its relative effectiveness. Continued imaging surveillance remains essential because reinterventions and device- or aorta-related abnormalities occurred during follow-up.

Indexed as

aortic archaortic remodellingcovered bridging stentin situ fenestrationthoracic endovascular aortic repair

Identifiers

PMID42741076
PMCPMC13572141

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.